Nome del prodotto
Valvola a sfera a 3 vie per uso sanitario – Acciaio inossidabile 316, attacco Tri-Clamp, attacchi L/T
Riepilogo del prodotto
A sanitary 3-way ball valve in polished 316 stainless steel with a pneumatic actuator (double acting or spring return). Tri-Clamp ends, 1/2″–2″, L-port to divert or T-port to mix. Two seat options: a standard PTFE seat rated −20 °C to +180 °C, or a fully encapsulated PTFE seat with no cavity behind the ball — nothing trapped, nothing to grow in — rated −20 °C to +70 °C. The body opens for cleaning.
Richiedi un preventivo — risposta entro 24 ore →
ISO 9001 · CE · Produttore dal 1999
Descrizione del prodotto
A sanitary 3-way ball valve in polished 316 stainless steel, driven by a rack-and-pinion pneumatic actuator (double acting or spring return). Tri-Clamp ends let you break the line without tools, and the ball is available with an L-port to divert flow between two destinations, or a T-port to mix two streams into one.
The part that matters in hygienic service is what happens behind the ball — see below.
The Cavity Problem — and What a Fully Encapsulated Seat Does About It
In a standard ball valve there is a small gap between the ball and the body. When the valve closes, product sits in that gap. On a water line nobody cares. On a food, beverage or pharmaceutical line, that trapped product is where bacteria grow, where the last batch contaminates the next one, and where a sugar syrup crystallises solid.
A fully encapsulated seat fills that space with PTFE. The ball touches nothing but the seat — there is no cavity, so there is nothing to trap product. This is what the industry means by a non-retention ball valve.
It is not free, though: filling the cavity with PTFE lowers the temperature ceiling. Choose with your process temperature in front of you.
| Seat design | What happens behind the ball | Temperature range | Choose it for |
|---|---|---|---|
| Partial (standard) | A small cavity remains behind the ball. Media can sit in it when the valve is closed. | −20 °C to +180 °C | Water, air, and media where a trace of residue is not a problem. |
| Fully encapsulated | PTFE fills the space around the ball. No cavity, nothing to trap product. | −20 °C to +70 °C | Food, beverage, pharmaceutical, and viscous or crystallising media that must not stay behind in the valve. |
← Scorri la tabella per visualizzare tutte le colonne →
The judgement is not “food versus water” — it is whether your medium can be left sitting in a cavity, and how hot your line runs. A crystallising chemical needs a full seat as much as milk does. A hot CIP loop above 70 °C rules a full seat out. Tell us the medium and the temperature when you request a quote and we will confirm which seat you need.
Valve Specifications
| Articolo | Specifiche tecniche |
|---|---|
| Materiale della carrozzeria | ASTM 316 stainless steel, polished sanitary finish |
| Port configuration | 3-way, L-port (diverting) or T-port (mixing / diverting) |
| Fine connessione | Tri-Clamp (quick clamp) sanitary ends |
| Gamma di taglie | 1/2″ – 2″ |
| Materiale dei sedili | PTFE — partial or fully encapsulated (see the seat table above) |
| Temperature range | −20 °C to +180 °C with a partial seat; −20 °C to +70 °C with a fully encapsulated seat |
| Cleaning | Clean-out-of-place (COP) — the body bolts open so the ball and seats can be removed and cleaned |
| Montaggio dell'attuatore | ISO 5211 |
Actuator Specifications
| Articolo | Specifiche tecniche |
|---|---|
| Tipo | Rack-and-pinion, aluminium alloy body |
| Action | Double Acting (DA) or Spring Return (SR) |
| Spring return position | Normally closed or normally open — specify when ordering |
| Rotation | 90° |
| Air supply | 4 – 8 bar (approx. 60 – 116 psi) |
| Control | On/Off (standard); modulating with positioner (optional) |
| Options | Solenoid valve, limit switch box, positioner |
Cleaning: This Valve Comes Apart
The body bolts open. Undo the clamps, take the ball and the seats out, clean them, put it back — clean-out-of-place (COP). You can see the parts you cleaned, which is more than can be said for a valve you can only flush from the outside.
We do not claim this valve is suitable for automated clean-in-place (CIP) cycles. A ball valve has geometry that a CIP flow cannot reach; the honest answer is that it is designed to be opened.
L-Port or T-Port
- Porta L (deviatore): the bore is bent 90°, connecting the inlet to one of two outlets at a time. Use it to switch a line between two tanks, two fillers or two filter banks.
- T-Port (Mixing / Diverting): the bore is T-shaped, so it can join two ports together or feed either outlet. Use it to blend two streams into one.
Related: the same 3-way body in a threaded (non-sanitary) version is our valvola a sfera pneumatica a 3 vie; the hand-operated sanitary version is the sanitary manual 3-way ball valve. For a two-way sanitary valve, see the valvola a sfera pneumatica per uso sanitario.
Applicazioni
- Batch changeover: switching a filler between two product tanks without cross-contaminating the next batch.
- Blending: combining two ingredient streams into one line with a T-port.
- Viscous and crystallising media: syrups, sauces and concentrates that would set solid in a standard valve cavity.
- Sterile area automation: remote open–close on a PLC signal, so nobody has to enter the room to turn a handle.
Domande frequenti
What is a non-retention (fully encapsulated) ball valve?
It is a ball valve in which PTFE fills the space around the ball, so there is no cavity behind it for product to sit in. Nothing is trapped when the valve closes — no residue, no place for bacteria to grow, no crystallised syrup. The trade-off is temperature: our fully encapsulated seat is rated −20 °C to +70 °C, against −20 °C to +180 °C for the standard partial seat.
Should I choose a partial seat or a fully encapsulated seat?
Ask two questions. First: can my medium be left sitting in a small cavity when the valve is closed? If it grows bacteria, crystallises, sets solid, or would contaminate the next batch, you need a fully encapsulated seat. Second: how hot does the line run? Above 70 °C the fully encapsulated seat is out, and you take the partial seat. Tell us the medium and the temperature and we will confirm.
Can this valve be cleaned in place (CIP)?
We do not claim it as a CIP valve. It is designed to be opened: undo the clamps, take the ball and seats out, clean them, reassemble. That is clean-out-of-place (COP), and it lets you inspect what you cleaned.
What is the difference between an L-port and a T-port?
An L-port bore is bent 90° and connects the inlet to one of two outlets at a time — it diverts. A T-port bore is T-shaped and can join two ports together — it can mix as well as divert. Choose L-port for switching, T-port for blending.
What sizes and end connections are available?
1/2″ to 2″, with Tri-Clamp (quick clamp) sanitary ends. The body is polished 316 stainless steel.
Can the actuator be set to fail closed?
Yes. Spring return (SR) units can be built normally closed or normally open — tell us which position the valve must take when the air supply is lost, and we will build it that way. Double acting (DA) units hold their last position instead.
What certifications do you hold?
ISO 9001 and CE, and we have been manufacturing stainless steel valves in Taiwan since 1999.
The valve itself: a polished 316 stainless body, PTFE seats (partial or fully encapsulated), no threads anywhere in the wetted path, and a body that bolts open so every product-contact surface can be reached, cleaned and inspected.
See all 3-way ball valve models — manual, pneumatic, sanitary & vacuum →
Politica di esempio
Siamo lieti di fornire ai clienti campioni di prodotto per valutare la qualità o effettuare test. Il processo inizia in genere con un preventivo basato sulle specifiche del cliente.
Se il prezzo è accettabile, possiamo offrire campioni gratuiti o a pagamento, a seconda del tipo di prodotto e della disponibilità.
Le spese di spedizione sono a carico del cliente.
Processo d'ordine
Dopo aver confermato i requisiti del prodotto e altri dettagli con il cliente, emetteremo una conferma di vendita per approvazione. Una volta confermata, il cliente è tenuto a versare un deposito 30% per procedere con la produzione.
Quando la produzione di massa è completata e la merce supera l'ispezione, il cliente deve pagare il saldo 70% prima di organizzare la spedizione.
Prodotti correlati
-
Valvole a sfera per uso sanitario (Tri-Clamp)
Valvola a farfalla pneumatica — Corpo a wafer, acciaio inossidabile 316, raccordo sanitario
-
Valvole a sfera per uso sanitario (Tri-Clamp)
Valvola a sfera a 3 vie per uso sanitario — Manuale, con attacchi a L o a T, Tri-Clamp, 316
-
Valvole a sfera per uso sanitario (Tri-Clamp)
Valvola a sfera pneumatica (attuata) per uso sanitario, acciaio inossidabile 316 – Attacco Tri-Clamp / a saldare, montaggio ISO 5211
-
Valvole a sfera per uso sanitario (Tri-Clamp)
Valvola a sfera per uso sanitario — Manuale a 3 pezzi, attacco Tri-Clamp / saldatura di testa (tubo OD), 316 a passaggio totale
Domande frequenti
A. Come posso richiedere un preventivo?
Si prega di fornire una scheda di richiesta dettagliata che includa le specifiche del prodotto, i materiali, le quantità ed eventuali requisiti speciali. Vi offriremo un'offerta basata sulla vostra richiesta.
B. Quali sono i termini di quotazione?
I nostri preventivi si basano in genere su Condizioni FOB. Tuttavia, possiamo anche offrire CFR, CIFo altri Incoterms su richiesta.
C. Qual è la vostra quantità minima d'ordine (MOQ)?
Non abbiamo un MOQ. Lavoriamo su ordinazione e accettiamo ordini di qualsiasi dimensione. benvenuto. Per gli ordini più piccoli, il trasporto è organizzato e a carico dell'acquirente.
D. Quali sono i termini di pagamento?
Per T/T - 30% acconto sulla conferma d'ordine e 70% saldo prima della spedizione.
E. Qual è il vostro tempo di consegna?
I tempi di consegna dipendono dalla quantità ordinata e dalle specifiche. Vi confermeremo i tempi esatti quando Richiedi un preventivo.
Volete saperne di più?
Se siete interessati a uno dei nostri prodotti o servizi, compilate il modulo sottostante. Il nostro team si metterà in contatto con voi il prima possibile per fornirvi le informazioni di cui avete bisogno.