Nom du produit

Manual Vacuum Valve – 3-Piece Vacuum Isolation Ball Valve, KF NW16–NW50 & ISO-K ISO80, 316, Lever or ISO 5211 Pad (V-3A / V-3AM)

Référence : V-3A/V-3AM NW
UGS V-3A/V-3AM NW Catégorie Marque :

Résumé du produit

A manual vacuum valve in a three-piece 316 stainless ball design: full port, PTFE seats, KF clamp flanges NW16 / NW25 / NW40 / NW50 (1/2″–2″) or ISO-K ISO80 (2-1/2″). Two builds on one body — the V-3A with a stainless lever, and the V-3AM with an ISO 5211 pad that takes a pneumatic or electric actuator with no bracket. The body unbolts for cleaning without cutting the valve out of the line. For fore-line, roughing-line and pump isolation, not as a high-vacuum chamber gate.

ISO 9001 · CE · Manufacturer since 1999 · Made in Taiwan

Manual Vacuum Valve or Direct-Mount? Two Builds, One Body (V-3A / V-3AM)

This manual vacuum valve is a three-piece 316 stainless ball valve with KF (NW16–NW50) or ISO-K (ISO80) clamp flanges, built to isolate a section of vacuum line by hand. The same body comes in two builds: the V-3A with a stainless lever, and the V-3AM with an ISO 5211 mounting pad so a pneumatic or electric actuator can be bolted on later without a bracket. Pick by how the line will be operated — now and after the next upgrade.

V-3A (manuel) V-3AM (montage direct)
Fonctionnement Levier en acier inoxydable à quart de tour avec plaque de verrouillage Support ISO 5211 pour actionneur pneumatique ou électrique — levier inclus pour utilisation manuelle
Joint d'étanchéité de tige Garniture en PTFE Joint torique en Viton et garniture en PTFE
Idéal pour Hand-operated isolation points on pump lines and manifolds Lignes qui sont — ou pourraient être à l'avenir — automatisées

Caractéristiques techniques principales

Type Manual vacuum valve — three-piece vacuum isolation ball valve, full port
Modèles V-3A (manual lever) / V-3AM (ISO 5211 direct-mount pad, lever included)
Gamme de tailles 1/2″ – 2-1/2″
Raccords d'extrémité KF clamp flange: NW16 (KF16) at 1/2″, NW25 (KF25) at 1″, NW40 (KF40) at 1-1/4″, NW50 (KF50) at 1-1/2″ and 2″. ISO-K flange: ISO80 at 2-1/2″.
Corps, culot et balle ASTM A351 CF8M (cast 316 stainless steel) as standard; CF8 (cast 304) made to order
Siège et joints PTFE
Tige ASTM A276 SS316; V-3AM adds a Viton O-ring for a reinforced stem seal
Port Full port — unrestricted bore through the valve
Température de fonctionnement −20 °C to +180 °C (valve body, set by the PTFE seats)
Service Vacuum and negative-pressure isolation — on/off duty, not for throttling
Fixation de l'actionneur V-3AM: ISO 5211 pad, direct mount, no bracket
Dimension sheets See the PDF downloads above (V-3A KF / ISO-K, V-3AM NW)

Isolation Valve Design: Why a Three-Piece Ball Valve

A ball valve is the plain answer for an isolation point on a fore-line, roughing line or manifold: a quarter turn opens or closes it, and in the open position the full-port bore leaves nothing in the gas path, so the valve does not choke the pumping speed of the line it sits in. That is the job this valve is built for — shutting a section in or out — not regulating flow.

The three-piece body is the service advantage. The two end caps stay clamped in the line while the centre section unbolts, so seats and ball can be inspected, cleaned or replaced without cutting the valve out or disturbing the flanges on either side. On a KF or ISO-K line that is an afternoon job with hand tools, not a rebuild.

Seats and gaskets are PTFE, the stem is SS316, and the V-3AM adds a Viton O-ring on the stem for a reinforced seal where an actuator will be cycling it. The body, cap and ball are cast 316 (CF8M) as standard, with 304 (CF8) available to order.

KF NW16–NW50 or ISO-K ISO80 Ends

KF (also written NW, QF or ISO-KF) is the small quick-clamp vacuum flange: a centering ring with an O-ring sits between two flanges and a clamp closed by hand holds them together, no bolts and no tools. This valve covers KF16, KF25, KF40 and KF50 — the sizes vacuum lines are built from — at 1/2″ to 2″.

ISO-K is the larger clamp-flange standard that takes over where KF ends. The 2-1/2″ size here uses ISO80, held with clamps and a centering ring. Match the valve to the flange already on your line; the same three-piece body and the same lever or ISO 5211 pad sit behind either end.

Applications

Where a manual vacuum valve of this type is actually used, and why a ball valve is the right tool there:

  • Foreline and roughing-line isolation: between the backing pump and the system, so the pump can be serviced or vented while the line upstream stays under vacuum.
  • Sample-entry locks: a low-cost load lock: open to pump down, close to vent and change the sample; the full bore keeps pump-down fast.
  • Coating and heat-treating equipment: isolation points on vacuum coaters and furnaces, and on their leak-testing and gas-analysis lines.
  • “Dirty” process lines: CVD / PVD chambers, scrubbers and particulate traps, where a PTFE-seated ball valve tolerates deposits better than a bellows-sealed valve because the seats wipe the ball each time it turns.
  • Helium leak-detection setups: the on/off valve between a calibrated leak or test piece and the detector, on KF flanges that connect and disconnect by hand.
  • Gauge isolation and gas inlet / vent points: blocking a gauge so it can be fitted or removed, or admitting and venting gas on laboratory systems; the locking plate on the lever guards against accidental operation.
  • Chambers that get disconnected and moved: for example glovebox-integrated coating systems, where a valve at each end lets the chamber be closed off, unclamped and carried across under vacuum.
  • Points that will be automated later: the V-3AM’s ISO 5211 pad takes a pneumatic or electric actuator when the line moves to PLC control; a quarter-turn on/off valve is the natural fit for that.

Related: for a pneumatic version of this valve see the vacuum rated ball valve, pneumatic (KF & ISO-K); for switching between two vacuum lines see the 3-way vacuum ball valve, manual or pneumatic (KF NW40 / NW50). For the larger ISO-K sizes in a hand-operated two-piece body see the vacuum isolation valve, ISO-K DN80/DN100. KF/NW centering rings are stocked to match. Browse all vannes à vide.

FAQ

Quelle est la différence entre les brides KF (NW) et ISO-K ?

Il s'agit dans les deux cas de brides à vide de type à serrage. La norme KF (également désignée par NW ou QF) concerne les petites tailles — de NW16 à NW50 sur cette vanne —, qui sont étanchéifiées à l'aide d'une bague de centrage et serrées à la main. La série ISO-K correspond aux plus grandes tailles ; la taille 2-1/2″ présentée ici utilise la norme ISO80. Choisissez la bride adaptée aux raccords déjà utilisés dans votre système.

Montage manuel ou direct : lequel choisir ?

Choose the V-3A lever version for hand-operated isolation points. Choose the V-3AM if the valve is — or may later be — automated: its ISO 5211 pad takes a pneumatic or electric actuator directly, with no bracket to fabricate. The V-3AM ships with a lever too, so it works by hand until the actuator goes on.

Est-ce un port complet ?

Yes. The bore is unrestricted through the valve, so in the open position the valve does not reduce the conductance of the line it sits in. Bore diameters for each size are on the dimension sheet PDF above.

La vanne peut-elle faire l'objet d'un entretien ?

Yes. The three-piece body unbolts while the end caps stay clamped in the line, so the seats and ball can be inspected, cleaned or replaced without cutting the valve out.

Quels joints utilise-t-on ?

Siège, joints et garniture en PTFE sur les deux versions ; le modèle V-3AM est équipé en plus d'un joint torique en Viton sur la tige pour une étanchéité renforcée sous vide.

Y a-t-il une quantité minimale de commande ?

Non. Nous n'imposons pas de quantité minimale de commande. Dites-nous ce dont vous avez besoin et nous vous établirons un devis.

What is the operating temperature range?

Valve body −20 °C to +180 °C, set by the PTFE seats.

Is it available in 304 stainless?

316 (cast CF8M) is standard. 304 (cast CF8) is made to order — tell us the size, flange and quantity when you request a quote.

Exemple de politique

Nous sommes heureux de fournir des échantillons de produits aux clients pour qu'ils puissent évaluer la qualité ou effectuer des tests. Le processus commence généralement par un devis basé sur les spécifications du client.

Si le prix est acceptable, nous pouvons proposer des échantillons gratuits ou payants en fonction du type de produit et de sa disponibilité.
Les frais d'expédition sont à la charge du client.

Processus de commande

Après avoir confirmé les exigences du produit et d'autres détails avec le client, nous émettons une confirmation de vente pour approbation. Une fois la confirmation obtenue, le client doit verser un acompte de 30% pour lancer la production.

Lorsque la production de masse est achevée et que les marchandises ont passé l'inspection, le client doit payer le solde 70% avant que l'expédition ne soit organisée.

FAQ

Veuillez fournir une demande détaillée comprenant les spécifications du produit, les matériaux, les quantités et toute exigence particulière. Nous vous proposerons un devis sur la base de votre demande.

Nos devis sont généralement basés sur Conditions FOB. Cependant, nous pouvons également offrir CFR, CIFou d'autres Incoterms sur demande.

MOQ depends on the product. We operate on a made-to-order basis, and trial orders are welcome. For smaller orders, freight is arranged and borne by the buyer.

Par T/T - 30% d'acompte à la confirmation de la commande, et 70% de solde avant l'expédition.

Le délai de livraison dépend de la quantité commandée et des spécifications. Nous vous confirmerons le calendrier précis lorsque vous demander un devis.

Vous voulez en savoir plus ?

Si vous êtes intéressé par l'un de nos produits ou services, il vous suffit de remplir le formulaire ci-dessous. Notre équipe prendra contact avec vous dans les plus brefs délais pour vous fournir les informations dont vous avez besoin.

Défiler vers le haut