製品名

Vacuum Isolation Valve – Manual Two-Piece Ball Valve, ISO-K ISO80 / ISO100 (DN80 / DN100), 316, Lever Handle (V-2V)

SKU: V-2V
SKU V-2V カテゴリー ブランド:

製品概要

A manual vacuum isolation valve in a two-piece 316 stainless ball design: full port, PTFE seats and PTFE vacuum seals, ISO-K clamp flanges ISO80 (DN80, 3″) or ISO100 (DN100, 4″), stainless lever handle. A quarter turn shuts a large ISO-K vacuum line in or out by hand, and the compact body drops straight into a standard ISO-K line with no adapters. For pump, fore-line and manifold isolation on DN80 and DN100 lines, not as a high-vacuum chamber gate.

ISO 9001 · CE · Manufacturer since 1999 · Made in Taiwan

Vacuum Isolation Valve for Large ISO-K Lines: Where the V-2V Fits

The V-2V is a manual vacuum isolation valve in a two-piece 316 stainless ball design, built for the large ISO-K clamp flanges: ISO80 (DN80, 3″) and ISO100 (DN100, 4″). A quarter turn of the stainless lever shuts a section of vacuum line in or out by hand, and the full bore leaves nothing in the gas path when open. It is the hand-operated valve for the big pump lines and manifolds that KF sizes do not reach. Pick by flange size and by how the line is operated:

This valve (V-2V) Three-piece (V-3A / V-3AM) Pneumatic (V-2BN-ISOK / V-2VN)
Flange sizes ISO-K ISO80 / ISO100 (DN80 / DN100) KF NW16–NW50 and ISO-K ISO80 KF NW50 and ISO-K DN80 / DN100
操作 Stainless lever, quarter-turn Lever, or ISO 5211 pad for a later actuator Pneumatic actuator, double acting or spring return
最適 Hand-operated isolation on large ISO-K pump lines and manifolds Small KF lines; body unbolts for service Lines switched by a PLC or a control signal

主要技術仕様

種類 Manual vacuum isolation valve: two-piece ball valve, full port
モデル V-2V
サイズ DN80 (3″) and DN100 (4″)
端部の接続 ISO-K clamp flange: ISO80 on DN80, ISO100 on DN100
ボディ&ボール CF8M (cast 316 stainless steel) as standard; CF8 (cast 304) made to order
シートとシール PTFE seats and PTFE vacuum seals
ポート Full port: unrestricted bore through the valve
操作 Stainless steel lever handle, quarter-turn; manual only
動作温度 −20 °C to +180 °C (valve body, set by the PTFE seats)
サービス Vacuum and negative-pressure isolation: on/off duty, not for throttling
Automated version Same ISO-K body with a pneumatic actuator: see the vacuum rated ball valve, pneumatic

Why a Two-Piece Ball Valve as a Vacuum Isolation Valve

An isolation valve has one job: shut a section of the system in or out, fully open or fully closed. A ball valve does that with a quarter turn, and in the open position the full-port bore puts nothing in the gas path, so the valve does not choke the pumping speed of the line it sits in. On a DN80 or DN100 line that matters: the whole point of a large ISO-K flange is conductance, and a valve with a reduced bore would give part of it back.

The two-piece body keeps the valve short and compact for its flange size. The body and end cap close around the ball and seats, with an ISO-K flange on either end, so the valve drops straight into a standard ISO-K line with claw clamps and a centering ring, no adapters and no welding. Seats and vacuum seals are PTFE; body and ball are cast 316 (CF8M) as standard, with 304 (CF8) made to order.

ISO-K ISO80 and ISO100 Ends: a DN80 or DN100 Ball Valve for Vacuum Lines

ISO-K is the clamp-flange standard for vacuum lines larger than the KF (NW) series. The flange has a grooved outer edge that claw clamps grip, and the seal is a centering ring with an O-ring held between the two flanges: no bolts through the flange, no threads, no welding, and the joint opens with hand tools for maintenance. ISO80 is the DN80 (3″) size and ISO100 the DN100 (4″) size. Match the valve to the flange already on your line; for the smaller KF sizes and ISO80 in a three-piece body, see the manual vacuum valve, KF and ISO80.

アプリケーション

Where a manual isolation valve of this size and type is actually used on vacuum systems, and why a ball valve is the right tool there:

  • Fore-line and roughing-line isolation: between the backing pump and the system on DN80 and DN100 lines, so the pump can be serviced or vented while the line upstream stays under vacuum.
  • Gauge isolation: blocking a gauge port so the gauge can be fitted, removed or kept off the line while a section is vented.
  • Deposition-heavy process lines: roughing and exhaust piping on PVD, CVD, ALD and sputtering systems, where the PTFE seats wipe the ball clean on every turn and the full 3″ or 4″ bore keeps the conductance a large line was built for.
  • Points that will be automated later: the same ISO-K body is made with a pneumatic actuator, so a manual valve here can be swapped for the pneumatic version when the line moves to PLC control.

Not for throttling, since a ball valve is an on/off device, and not as the main isolation valve on a large coater or sputter chamber, where vacuum systems use pendulum or gate valves instead.

Related: for the same ISO-K body with a pneumatic actuator see the vacuum rated ball valve, pneumatic (KF & ISO-K); for switching between two vacuum lines see the 3方向真空ボールバルブ. KF/NW centering rings are stocked to match. Browse all 真空バルブ.

よくある質問

ISO80 or ISO100: which should I order?

Match the ISO-K flange size your line already uses: ISO80 is DN80 (3″), ISO100 is DN100 (4″). Both are available; state the size when you request a quote.

What is the difference between this and the three-piece vacuum valve?

This valve is a compact two-piece body for the large ISO-K flanges, ISO80 and ISO100. The three-piece manual vacuum valve covers the smaller KF sizes (NW16–NW50) plus ISO80, and its body unbolts in the line for servicing.

What is an ISO-K flange?

A clamp-style vacuum flange standard for larger bores. The flange has a grooved edge that claw clamps grip, sealing on a centering ring: no threads, no welding, and quick to open for maintenance.

どのようなシールが使われていますか?

PTFE, for both the seats and the vacuum seals, on a cast 316 stainless body.

フルポートですか?

Yes. The bore is unrestricted through the valve, so in the open position it does not reduce the conductance of the DN80 or DN100 line it sits in.

Can this valve be automated?

Not this build: the V-2V is manual only. If the line is or may later be automated, use the pneumatic vacuum rated ball valve (ISO-K DN80/DN100), which is the same body with an actuator.

What is the operating temperature range?

Valve body −20 °C to +180 °C, set by the PTFE seats.

Is it available in 304 stainless?

316 (cast CF8M) is standard. 304 (cast CF8) is made to order; tell us the size, flange and quantity when you request a quote.

最低注文数はいくらですか?

No minimum order quantity. We accept orders of any size, including small trial orders; tell us what you need and we will quote it.

サンプル・ポリシー

お客様の品質評価やテストのために、製品サンプルを喜んでご提供いたします。プロセスは通常、お客様の仕様に基づいたお見積もりから始まります。

価格設定にご納得いただければ、製品の種類や在庫状況に応じて、無料または有償でサンプルをご提供いたします。
送料はお客様のご負担となります。

ご注文の流れ

製品の要件やその他の詳細をお客様と確認した後、承認のための販売確認書を発行します。確認後、30%デポジットをお支払いいただき、生産を開始します。

大量生産が完了し、商品が検査に合格した場合、お客様は出荷手配前に残金70%を支払う必要があります。

よくある質問

製品仕様、材料、数量、特別なご要望を含む詳細なお問い合わせシートをご提示ください。お客様のご要望に基づき、お見積もりをさせていただきます。

私たちの見積もりは通常、以下の内容に基づいています。 本船渡し条件.しかし、我々はまた、提供することができる CFR、CIFまたはご要望に応じて他のインコタームズ。

MOQはありません。オーダーメイドで、どんなサイズのご注文でも承ります。 歓迎する。小口注文の場合、運賃は買い手が負担する。.

T/T - 注文確認時に30%の頭金を支払い、出荷前に70%の残金を支払う。

納期は注文数量や仕様によって異なります。お客様からご連絡をいただいた際に、正確なスケジュールをご確認させていただきます。 お見積りをご依頼ください。.

もっと知りたい?

当社の製品やサービスにご興味をお持ちの方は、下記のフォームにご記入ください。 必要な情報を提供するために、私たちのチームができるだけ早くご連絡させていただきます。

上部へスクロール