Last updated: 2026-11-22
Short answer: A motorized valve actuator is an electric drive that mounts on a valve and opens or closes it from a control signal, so nobody has to turn a handle. On a ball valve it turns the stem a quarter turn. YZNG TRONG builds on/off, quarter-turn motorized valve actuators in Taiwan for ball valves from 3/8″ to 2″. The YZ-25-CAP mounts on an ISO 5211 pad, runs on single-phase AC 110V or 220V, and drives the valve fully closed from a replaceable supercapacitor when the power is lost.
A motorized valve actuator replaces the hand on the handle. A controller switches the power, an electric motor turns the valve, and a signal comes back to say whether the valve is open or closed. The type you need depends on three things: how the valve moves, how it is controlled, and what it must do when the power fails.
What Is a Motorized Valve Actuator?
A motorized valve actuator is the electric drive unit that sits on top of a valve and moves it. Motorized means the force comes from an electric motor, where a pneumatic actuator uses compressed air. The actuator bolts to the mounting pad of the valve, its output drive engages the valve stem, and from then on the valve is operated by a signal from a PLC, a timer or a switch.
Buyers use several names for the same thing: motorised valve actuator in British spelling, electric valve actuator, or motor operated valve actuator. On a ball valve the usual form is a compact quarter-turn unit, because a ball valve goes from fully open to fully closed in 90 degrees.

How Does a Motorized Valve Actuator Work?
It turns an electrical command into a quarter turn of the valve stem, then reports the result. On an on/off unit such as the YZ-25-CAP the sequence has four steps.
- The controller gives the command. A PLC output switches the supply to the actuator to open or to close.
- The motor turns the gear train. The gears trade motor speed for torque, enough to break the ball loose from its seats.
- The output drive turns the stem 90 degrees. The ball goes from open to closed, or back.
- The actuator stops and reports. A dry contact tells the control panel that the valve is open or closed, and a window on top of the actuator shows the position on site.

How long the stroke takes depends on the model. On our actionneur électrique à batterie de secours, the YZ-25-AC and YZ-25-DC, full travel from open to closed takes 3 seconds.
Motorized Valve vs. Valve Actuator: What Is the Difference?
A motorized valve is the complete assembly, valve plus electric actuator. The valve actuator is only the drive on top. An actuated valve is the wider term, since the actuator on it can be pneumatic or electric.
The difference matters when you ask for a quote. Ordering the actuator alone leaves the fit to you. Ordering a motorized ball valve means the supplier matches the two. YZNG TRONG makes both the actuators and the stainless steel ball valves, so we supply the actuator on its own or mounted on a valve, assembled and tested before it ships. If you are still choosing between hand, air and electric operation, see our guide to manual, pneumatic and electric ball valves.
Types of Motorized Valve Actuators
Catalogs sort motorized valve actuators four ways: by motion, by control, by what happens on power loss, and by supply. The last column shows where the YZNG TRONG models sit.
| Sorted by | Options | What it means | YZNG TRONG models |
|---|---|---|---|
| Motion | Quarter-turn, multi-turn or linear | Quarter-turn units rotate the stem 90 degrees for ball valves. Multi-turn and linear units drive valves such as gate and globe valves. | Quarter-turn, for ball valves 3/8″ to 2″ |
| Contrôle | Tout ou rien ou modulé | On/off moves between fully open and fully closed. Modulating holds positions in between from an analog control signal. | On/off |
| Comportement en cas de coupure d'alimentation | Stays in place or fail-safe | A standard unit stops where it is. A fail-safe unit uses stored energy to move the valve to a set position. | Fail-safe: the valve is driven fully closed |
| Supply | AC or DC | The actuator has to match the supply available at the valve. | YZ-25-CAP: AC 110V / 220V single phase. YZ-25-AC: AC 110V / 220V / 380V single phase. YZ-25-DC: DC 24V / 48V |
What Happens to a Motorized Valve When the Power Fails?
A standard motorized valve stays where it was. The motor has no stored energy, so an open valve stays open through the outage. On a dosing line or a drain line that is the failure you are trying to prevent.
A fail-safe motorized valve actuator carries its own energy for the closing stroke. That energy is stored in a spring, a battery or a supercapacitor. YZNG TRONG builds two versions, and both drive the valve to the fully closed position with no air supply, no spring pack and no plant UPS: the YZ-25-CAP fail safe electric actuator with a supercapacitor, and the lithium battery version.

| Article | YZ-25-CAP | YZ-25-AC / YZ-25-DC |
|---|---|---|
| Backup energy | Supercapacitor, replaceable and sold as a spare part | Built-in lithium battery, approximately 5,000 operations on a full charge |
| Puissance absorbée | AC 110V / 220V, single phase, one unit accepts both | AC 110V / 220V / 380V single phase, or DC 24V / 48V |
| Température de fonctionnement | -30 °C to 50 °C | 0 °C to 45 °C |
| Comportement en cas de coupure d'alimentation | Valve driven to fully closed | Valve driven to fully closed |
| Dimensions des vannes | 3/8″ to 1-1/4″ (YZ-50-CAP for 1-1/2″ and 2″) | 3/8″ to 1-1/4″ |
| Status display | Position window on top | LCD battery level indicator |
Choose by site temperature and supply. The YZ-25-CAP is rated from -30 °C to 50 °C. The lithium version is rated from 0 °C to 45 °C and adds 380V and DC supply options.
Which Specs Should You Check Before Ordering?
Check nine things: torque, mounting, supply voltage, control type, power-loss position, backup energy, feedback signal, local indication and ambient temperature. The table gives the reason for each and the value on the YZ-25-CAP.
| Spec | Pourquoi est-ce important ? | YZ-25-CAP |
|---|---|---|
| Torque | The actuator has to overcome the breakaway torque of the valve, the peak needed to start the ball moving. | Matched to ball valves 3/8″ to 1-1/4″, 3.0 to 15.0 N·m breakaway torque |
| Montage | ISO 5211 sets the flange and drive dimensions for attaching part-turn actuators to valves, so both sides can be checked against one standard. | ISO 5211 mounting pad |
| Supply voltage | It has to match the supply at the valve location. | AC 110V / 220V, single phase. One unit accepts both |
| Type de commande | On/off and modulating are different actuators. | On/off (open–close), PLC controlled |
| Power-loss position | Decide what the valve must do in an outage before you order. | Driven to fully closed |
| Backup energy | It decides how the closing stroke is powered and what gets serviced later. | Supercapacitor, replaceable on site, sold as a spare part |
| Feedback signal | The control panel needs to know the valve reached its position. | Dry contact, open / closed, DC 24V / 48V, through an aviation plug with a dust and water cap |
| Local indication | Maintenance staff need to see the position at the valve. | Window on top of the actuator |
| Ambient temperature | The electronics and the stored energy both have a working range. | -30 °C to 50 °C |
How to Size a Motorized Valve Actuator for a Ball Valve
Start from the valve, and let its breakaway torque pick the actuator. Pipe size alone does not tell you, because two valves of the same size can need different torque.
- Write down the valve size, body type and end connection.
- Get the breakaway torque for that valve from its manufacturer.
- Choose the actuator model that covers that torque.
- Confirm the supply voltage at the valve location.
- Decide the power-loss position and the backup energy.
- Decide how the position gets back to the control panel.
For our own valves the second and third steps are already done. The figures below are the breakaway torque of the YZNG TRONG V-2AM and V-3AM ball valves (1000 WOG, PTFE seats, 316), the valves each actuator is matched to.
| Valve size | Valve breakaway torque | Actuator model |
|---|---|---|
| 3/8″ | 3.0 N·m | YZ-25-CAP |
| 1/2″ | 4.5 N·m | YZ-25-CAP |
| 3/4″ | 8.5 N·m | YZ-25-CAP |
| 1″ | 11.0 N·m | YZ-25-CAP |
| 1-1/4″ | 15.0 N·m | YZ-25-CAP |
| 1-1/2″ | 21.0 N·m | YZ-50-CAP |
| 2″ | 25.0 N·m | YZ-50-CAP |
We mount the actuator on the valve and test the assembly before it ships.
Common Mistakes When Ordering a Motorized Valve Actuator
- Sizing by pipe size alone. Ask for the breakaway torque of the valve, then choose the actuator.
- Assuming every electric actuator closes in an outage. A standard unit stays put. If the valve has to close, write fail-safe closed on the order.
- Reading the contact rating as the supply voltage. The plate beside the connector on the YZ-25-CAP reads DC24V and DC48V. That is the rating of the feedback contacts. The actuator itself runs on AC 110V or 220V.
- Ordering an on/off actuator for a flow-control duty. On/off means fully open or fully closed. If the process needs positions in between, say so at the start.
- Leaving ambient temperature for last. The backup energy sets the range: -30 °C to 50 °C on the YZ-25-CAP, 0 °C to 45 °C on the lithium version.
Where Motorized Ball Valves Are Used
Electric actuation is the usual choice where the line has power but no compressed air. These are the duties it is built for.
- Wastewater and sewage treatment. Dosing and drain lines that have to shut when the power goes. See our applications dans le domaine du traitement de l'eau.
- Industrial process lines. On/off duty where there is no compressed air on site. See our applications industrielles.
- Electronics and hi-tech facility piping. Cooling water and general utility lines where a valve has to return to closed after a power dip. See our applications des valves à semi-conducteurs.
- Food and beverage processing lines. Scheduled open and close cycles under PLC control. See our applications dans le secteur agroalimentaire.
- OEM machine builders. An actuator designed into a skid or a panel, with the YZ-25-CAP supercapacitor available later as a spare part.
Motorized Valve Actuator FAQ
Is a motorized valve actuator the same as an electric valve actuator?
Yes. Both names describe an actuator driven by an electric motor. Motorised valve actuator and motor operated valve actuator are other names buyers use for it.
Does a motorized valve close when the power goes out?
Only a fail-safe one does. A standard motorized valve stays in its last position. The YZ-25-CAP drives the valve fully closed from its built-in supercapacitor when the supply is lost.
What voltage does a motorized valve actuator use?
It depends on the model. The YZ-25-CAP runs on single-phase AC 110V or 220V, and one unit accepts both. The YZ-25-AC takes AC 110V, 220V or 380V single phase, and the YZ-25-DC takes DC 24V or 48V.
Is the actuator sold alone or with the valve?
Both. YZNG TRONG supplies the actuator on its own, or mounted on a stainless steel ball valve as one assembly. Tell us the valve size and end connection and we quote the two together.
Can the actuator carry our own brand?
Yes. YZNG TRONG makes the actuators in Taiwan and can supply them under your own brand as a private label product.
How much does a motorized valve actuator cost?
The price follows the torque, the backup energy and the supply voltage, and whether it ships with a valve. Send the valve size, end connection and supply voltage, and we will quote the assembly.
YZNG TRONG has made stainless steel ball valves in Taiwan since 1999 and builds the actuators that go on them.