製品名
バッテリーバックアップ機能付き電動バルブアクチュエータ
製品概要
Motorised Shut-Off That Closes Itself When the Power Goes Out.
Electric valve actuator with a built-in lithium battery backup, for quarter-turn ball valves 3/8″–1-1/4″. AC 110V/220V/380V single phase (YZ-25-AC) or DC 24V/48V (YZ-25-DC). On/off control with dry-contact feedback, 3-second full travel, LCD battery indicator, approximately 5,000 operations per charge. On power loss, the battery drives the valve to the fully closed position — no air supply, no spring, no plant UPS. Indoor installation.
ISO 9001・CE・1999年より製造
製品概要
The YZNG TRONG electric valve actuator automates on/off operation of quarter-turn ball valves in 3/8″ to 1-1/4″. It accepts AC 110V, 220V or 380V (single phase), or DC 24V or 48V. When mains power is lost, the built-in lithium battery drives the valve to the fully closed position — the line shuts, without an air supply, a spring, or an external UPS.
A full charge is good for approximately 5,000 operations, and full travel takes 3 seconds, open to close. An LCD on the actuator shows the battery level, and wiring runs through an aviation plug connector, so a technician can connect or disconnect without opening the cover.
What Happens When the Power Fails
This is the question that decides the purchase, so here is the direct answer: the valve closes. The lithium battery inside the actuator holds enough charge for approximately 5,000 operations on a full charge — so it is not a one-shot emergency reserve, it keeps working through repeated outages. No compressed air, no spring pack, no plant-wide UPS.
Four methods are used across the industry to keep a valve controllable when the power goes out. They work in different ways:
| Method | Where the energy comes from | What the valve does on power loss |
|---|---|---|
| 春の訪れ | A mechanical spring, wound during normal operation | The valve returns to the spring’s position |
| Battery backup — this actuator | A built-in lithium battery | The valve is driven to the fully closed position |
| Supercapacitor | A stored electrical charge, held for a short period | The valve moves to a preset position |
| External UPS | A separate uninterruptible power supply feeding the actuator | Depends on how the UPS and actuator are configured |
← テーブルをスワイプしてすべての列を表示 →
Spring return needs no electricity at all but is limited by the spring. Supercapacitors hold charge only briefly. An external UPS is a plant-level investment, not a feature of the valve. A battery inside the actuator keeps the shut-off function in the actuator itself — which is why it suits dosing lines, drain lines and skids where an uncontrolled valve position is the thing you cannot allow.
Models
| モデル | Power input |
|---|---|
| YZ-25-AC | AC 110V / 220V / 380V, single phase |
| YZ-25-DC | DC 24V / 48V |
Torque Ratings
| Output gear size | Rated torque | Maximum torque |
|---|---|---|
| 9 – 11 mm | 3 N·m | 20 N·m |
| 14 mm | 10 N·m | 20 N·m |
主要技術仕様
| 品目 | 仕様 |
|---|---|
| モデル | YZ-25-AC (AC input) / YZ-25-DC (DC input) |
| AC input | AC 110V / 220V / 380V, single phase |
| DC input | DC 24V / 48V |
| Power-loss behaviour | The built-in lithium battery drives the valve to the fully closed position |
| Backup power | Built-in lithium battery |
| Battery capacity | Approximately 5,000 operations on a full charge |
| Battery level display | LCD indicator on the actuator |
| Operating time | 3 seconds, full open to full close |
| Valve sizes | Fits 3/8″ – 1-1/4″ quarter-turn ball valves |
| Control type | オン/オフ(開閉) |
| Signal output | Dry contact (open / close feedback) |
| Wiring | 航空用プラグコネクター - カバーを取り外すことなく着脱可能 |
| 動作温度 | 0 °C – 45 °C |
| インストール | Indoor use only (the lithium battery is not rated for outdoor temperature swings) |
外形寸法(mm)

| Width | 152 mm |
| Height | 133 mm |
| Depth | 131 mm |
アプリケーション
- Wastewater treatment: automated dosing and drain lines where the valve must close if power is lost.
- Industrial on/off control: remote open–close of quarter-turn ball valves where there is no compressed air available — the usual reason to choose electric over pneumatic actuation.
- OEM equipment: machine builders adding motorised shut-off to a skid or panel.
- Food, beverage and pharmaceutical CIP lines: scheduled open–close cycles under PLC control.
Pairing the Actuator with a Valve
This product is the actuator only. It fits quarter-turn ball valves from 3/8″ to 1-1/4″ — for example our two-piece stainless ball valve または スリーピースボールバルブ, both of which have an ISO 5211 mounting pad. Tell us the valve size and end connection you need and we will quote the actuator and valve as one assembly. If you need position feedback in the control panel, add a リミットスイッチボックス.
よくある質問
What happens to the valve if main power fails?
The built-in lithium battery drives the valve to the fully closed position. A full charge is good for approximately 5,000 operations, so the valve keeps closing through repeated outages — it is not a single-shot emergency reserve.
Do I need a UPS for my valve actuator?
Not for this one. The backup battery is inside the actuator, so the shut-off function does not depend on a plant-wide uninterruptible power supply. An external UPS keeps the whole control system alive; this actuator only needs to guarantee that the valve closes, and it carries its own energy to do that.
How many times can the battery operate the valve after a power cut?
Approximately 5,000 operations on a full charge. The battery is not a single-shot emergency reserve — it keeps the valve working through repeated outages, and an LCD on the actuator shows the remaining level.
How fast does the actuator open and close the valve?
3 seconds for full travel, open to close.
Which valve sizes does this actuator fit?
Quarter-turn ball valves from 3/8″ to 1-1/4″. Tell us the valve size and end connection and we will quote the actuator and valve together.
What voltages does this actuator support?
AC 110V, 220V or 380V (single phase) — model YZ-25-AC. Or DC 24V or 48V — model YZ-25-DC.
What torque does the actuator deliver?
Maximum torque is 20 N·m for both output gear sizes. Rated torque depends on the gear: 14 mm is rated 10 N·m, 9–11 mm is rated 3 N·m.
Can I install this actuator outdoors?
No. It is designed for indoor installation. The lithium battery inside is not rated for outdoor temperature swings, and the operating range is 0 °C to 45 °C.
Is this a complete electric ball valve, or just the actuator?
The actuator only, sold separately from the valve body. We can supply it mounted on a ball valve as a complete assembly — tell us the valve size and end connection when you request a quote.
How is the actuator wired?
Through an aviation plug connector, which lets a technician connect or disconnect the wiring without removing the actuator cover. Signal output is a dry contact giving open and close feedback.
サンプル・ポリシー
お客様の品質評価やテストのために、製品サンプルを喜んでご提供いたします。プロセスは通常、お客様の仕様に基づいたお見積もりから始まります。
価格設定にご納得いただければ、製品の種類や在庫状況に応じて、無料または有償でサンプルをご提供いたします。
送料はお客様のご負担となります。
ご注文の流れ
製品の要件やその他の詳細をお客様と確認した後、承認のための販売確認書を発行します。確認後、30%デポジットをお支払いいただき、生産を開始します。
大量生産が完了し、商品が検査に合格した場合、お客様は出荷手配前に残金70%を支払う必要があります。
関連商品
該当する商品は見つかりませんでした。
よくある質問
A.見積もり依頼の方法を教えてください。
製品仕様、材料、数量、特別なご要望を含む詳細なお問い合わせシートをご提示ください。お客様のご要望に基づき、お見積もりをさせていただきます。
B.見積条件は何ですか?
私たちの見積もりは通常、以下の内容に基づいています。 本船渡し条件.しかし、我々はまた、提供することができる CFR、CIFまたはご要望に応じて他のインコタームズ。
C.最小発注量(MOQ)はいくらですか?
MOQはありません。オーダーメイドで、どんなサイズのご注文でも承ります。 歓迎する。小口注文の場合、運賃は買い手が負担する。.
D.支払条件を教えてください。
T/T - 注文確認時に30%の頭金を支払い、出荷前に70%の残金を支払う。
E.リードタイムはどのくらいですか?
納期は注文数量や仕様によって異なります。お客様からご連絡をいただいた際に、正確なスケジュールをご確認させていただきます。 お見積りをご依頼ください。.
もっと知りたい?
当社の製品やサービスにご興味をお持ちの方は、下記のフォームにご記入ください。 必要な情報を提供するために、私たちのチームができるだけ早くご連絡させていただきます。