{"id":3850,"date":"2025-10-17T09:24:34","date_gmt":"2025-10-17T01:24:34","guid":{"rendered":"https:\/\/ballvalves.tw\/?post_type=product&#038;p=3850"},"modified":"2026-09-12T01:47:47","modified_gmt":"2026-09-11T17:47:47","slug":"%e6%b0%a3%e5%8b%95%e7%9c%9f%e7%a9%ba%e9%96%a5","status":"publish","type":"product","link":"https:\/\/ballvalves.tw\/zh\/product\/pneumatic-vacuum-valve\/","title":{"rendered":"Vacuum Rated Ball Valve, Pneumatic \u2013 NW50 KF (2\u2033), ISO-K DN80 \/ DN100, 316 Two-Piece (V-2VN \/ V-2BN-ISOK)"},"content":{"rendered":"<div style=\"display: flex;flex-wrap: wrap;align-items: stretch;gap: 12px;margin: 18px 0\"><a style=\"display: block;min-width: 230px;flex: 1 1 calc(33.333% - 8px);padding: 17px 19px;background: #f3f8fd;border: 1px solid #c7dcef;border-left: 5px solid #1261a0;border-radius: 9px;color: #17324d!important;text-decoration: none;cursor: pointer\" href=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/06\/V-2VN-Pneumatic-Vacuum-Ball-Valve.pdf\" target=\"_blank\" rel=\"noopener\"><span style=\"display: inline-block;margin-right: 10px;padding: 6px 9px;background: #1261a0;color: #ffffff!important;border-radius: 5px;font-size: 12px;font-weight: bold;letter-spacing: .5px\">PDF<\/span><strong style=\"color: #17324d!important;font-size: 17px\">V-2VN<\/strong><span style=\"display: block;margin-top: 10px;color: #5d7185!important;font-size: 13px\">NW50 ISO-KF (2\u2033) \u00b7 Dimension Sheet <strong style=\"color: #1261a0!important\">\u4e0b\u8f09 PDF \u2193<\/strong><\/span><\/a><\/div>\n<p>This vacuum rated ball valve is a two-piece 316 stainless steel pneumatic ball valve built for vacuum lines. It comes with two end styles: NW50 (ISO-KF \/ KF50) clamp flanges at 2\u2033 (model V-2VN), or ISO-K flanges at ISO80 (DN80, 3\u2033) and ISO100 (DN100, 4\u2033) (model V-2BN-ISOK). Both share the same full-port body, PTFE seats and an ISO 5211 pad that takes a rack-and-pinion air actuator, double acting (DA) or spring return (SR), so the valve opens and closes on a signal instead of by hand.<\/p>\n<h2>Where This Vacuum Pump Isolation Valve Belongs in the System<\/h2>\n<p>A vacuum ball valve has a clear place in a vacuum system: on the pump side. Here is where this valve is used and what it does there.<\/p>\n<div>\n<table style=\"min-width: 700px;width: 100%;border-collapse: collapse\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #ddd;padding: 8px\">\u5728\u7cfb\u7d71\u4e2d\u7684\u4f4d\u7f6e<\/th>\n<th style=\"border: 1px solid #ddd;padding: 8px\">What the valve does there<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\"><strong>\u524d\u7aef\u7dda\uff0f\u7c97\u52a0\u5de5\u7dda\u9694\u96e2<\/strong><\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Between the pump and the chamber, on the roughing or backing line: this is what a vacuum ball valve is for.<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\"><strong>\u771f\u7a7a\u6cf5\u9694\u96e2<\/strong><\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u5c07\u6cf5\u6d66\u5f9e\u7ba1\u7dda\u4e2d\u9694\u96e2\uff0c\u4ee5\u4fbf\u5728\u4e0d\u9700\u5c0d\u6574\u500b\u7cfb\u7d71\u9032\u884c\u6392\u6c23\u7684\u60c5\u6cc1\u4e0b\u9032\u884c\u7dad\u4fee\u6216\u66f4\u63db\u3002.<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\"><strong>\u91cf\u5177\u9694\u96e2<\/strong><\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u5728\u7c97\u62bd\u6216\u6392\u6c23\u904e\u7a0b\u4e2d\u4fdd\u8b77\u771f\u7a7a\u8a08\u3002.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"font-size: 13px;color: #666;margin: 6px 0 28px\">\u2190 \u6ed1\u52d5\u8868\u683c\u4ee5\u67e5\u770b\u6240\u6709\u6b04\u4f4d \u2192<\/p>\n<p>For isolating a pump, a fore-line or a gauge, a ball valve is the straightforward, fast, full-bore answer, and with a pneumatic actuator it does that on a signal.<\/p>\n<h2>\u4e3b\u8981\u6280\u8853\u898f\u683c<\/h2>\n<div>\n<table style=\"width: 100%;border-collapse: collapse\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #ddd;padding: 8px\">\u9805\u76ee<\/th>\n<th style=\"border: 1px solid #ddd;padding: 8px\">\u898f\u683c<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u985e\u578b<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Two-piece vacuum ball valve, pneumatically actuated (V-2VN \/ V-2BN-ISOK)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u8eca\u8eab\u6750\u8cea<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">ASTM A351 CF8M\uff08316 \u4e0d\u93fd\u92fc\uff09<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u9023\u63a5<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">NW50 (ISO-KF \/ KF50) clamp flange \u2014 2\u2033 (V-2VN)<br \/>\nISO-K vacuum flange \u2014 ISO80 (DN80, 3\u2033) or ISO100 (DN100, 4\u2033) (V-2BN-ISOK)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u6e2f\u53e3<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Full port on all sizes<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u5ea7\u5708\u8207\u5bc6\u5c01\u5708<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">PTFE<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u5de5\u4f5c\u6eab\u5ea6<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Valve \u221220 \u00b0C to +180 \u00b0C \u00b7 Actuator \u221220 \u00b0C to +80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u81f4\u52d5\u5668<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Rack-and-pinion, aluminium alloy body, double acting (DA) or spring return (SR)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u4f9b\u6c23<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">4 \u2013 8 \u5df4\uff08\u7d04 58 \u2013 116 \u78c5\/\u5e73\u65b9\u82f1\u540b\uff09<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u81f4\u52d5\u5668\u5b89\u88dd<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">ISO 5211 \u2014 \u57f7\u884c\u5668\u53ef\u76f4\u63a5\u9396\u56fa\u65bc\u95a5\u9ad4\u4e0a\uff0c\u7121\u9700\u652f\u67b6\u6216\u806f\u8ef8\u5668<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u5f48\u7c27\u56de\u4f4d\u4f4d\u7f6e<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u5e38\u9589\u6216\u5e38\u958b \u2014 \u8a02\u8cfc\u6642\u8acb\u8a3b\u660e<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u9078\u9805<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u96fb\u78c1\u95a5\u3001\u9650\u4f4d\u958b\u95dc\u76d2\u3001\u5b9a\u4f4d\u5668<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u670d\u52d9<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">\u5728\u771f\u7a7a\u7ba1\u7dda\u4e0a\u9032\u884c\u81ea\u52d5\u5206\u96e2\u8207\u5b9a\u5e8f<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Vacuum Rated Valve Design: Why a Pneumatic Ball Valve<\/h2>\n<ul>\n<li><strong>\u901f\u5ea6\uff1a<\/strong> \u771f\u7a7a\u64cd\u4f5c\u5e8f\u5217\u662f\u6309\u6642\u9593\u63a7\u5236\u7684\u3002\u4f7f\u7528\u624b\u52d5\u95a5\u9580\u6642\uff0c\u64cd\u4f5c\u54e1\u6703\u6210\u70ba\u74f6\u9838\uff1b\u800c\u4f7f\u7528\u6c23\u52d5\u57f7\u884c\u5668\u5247\u4e0d\u6703\u3002.<\/li>\n<li><strong>\u76f4\u63a5\u5b89\u88dd\uff1a<\/strong> \u95a5\u9ad4\u4e0a\u5df2\u914d\u5099 ISO 5211 \u588a\u7247\uff0c\u56e0\u6b64\u57f7\u884c\u5668\u53ef\u76f4\u63a5\u4ee5\u87ba\u6813\u56fa\u5b9a\uff0c\u7121\u9700\u652f\u67b6\u3001\u7121\u9700\u806f\u8ef8\u5668\uff0c\u4e5f\u7121\u9700\u9032\u884c\u4efb\u4f55\u5c0d\u4f4d\u64cd\u4f5c\u3002.<\/li>\n<li><strong>\u6c23\u58d3\u640d\u5931\u6642\u7684\u5f48\u7c27\u56de\u4f4d\uff1a<\/strong> \u7576\u6c23\u6e90\u4e2d\u65b7\u6642\uff0cSR \u55ae\u5143\u6703\u79fb\u52d5\u81f3\u60a8\u6307\u5b9a\u7684\u4f4d\u7f6e\u3002\u8acb\u544a\u77e5\u6211\u5011\u8a72\u4f4d\u7f6e\u662f\u958b\u555f\u72c0\u614b\u9084\u662f\u95dc\u9589\u72c0\u614b\uff0c\u6211\u5011\u5c07\u64da\u6b64\u9032\u884c\u88fd\u9020\u3002.<\/li>\n<li><strong>\u5168\u5b54\u5f91\uff1a<\/strong> \u6c92\u6709\u4efb\u4f55\u56e0\u7d20\u6703\u4f7f\u7dda\u5f91\u8b8a\u7a84\uff0c\u56e0\u6b64\u96fb\u5c0e\u7387\u4e0d\u6703\u56e0\u95a5\u9580\u800c\u53d7\u5230\u5f71\u97ff\u3002.<\/li>\n<li><strong>316 \u4e0d\u93fd\u92fc\uff0cPTFE \u95a5\u5ea7\uff1a<\/strong> a clean, corrosion-resistant combination for vacuum service.<\/li>\n<\/ul>\n<h2>Pneumatic Vacuum Valve Ends: NW50 KF or ISO-K<\/h2>\n<p><strong>NW50 (ISO-KF \/ KF50), 2\u2033 \u2014 V-2VN.<\/strong> The KF clamp flange seals with a single clamp and a centring ring, no bolts, so the valve connects straight into a standard KF line and opens tool-free for service. The dimension sheet above gives face-to-face length, height to actuator top, flange O.D. and tube O.D.<\/p>\n<p><strong>ISO-K ISO80 (DN80, 3\u2033) and ISO100 (DN100, 4\u2033) \u2014 V-2BN-ISOK.<\/strong> The ISO-K flange clamps straight into a standard ISO-K line, no adapter needed, for the larger fore-lines and pump connections where KF sizes run out.<\/p>\n<h2>\u61c9\u7528<\/h2>\n<ul>\n<li><strong>\u771f\u7a7a\u6cf5\u9694\u96e2<\/strong> \u2014 shutting a pump out of the line for service without venting the system.<\/li>\n<li><strong>Roughing and backing lines<\/strong> \u2014 isolating rotary-vane or scroll pumps from the chamber.<\/li>\n<li><strong>Freeze-drying systems<\/strong> \u2014 isolating the vacuum line between the freeze dryer and its pump.<\/li>\n<li><strong>Vacuum ovens<\/strong> \u2014 shutting off chamber vacuum before the pump is switched off.<\/li>\n<li><strong>Laboratory vacuum piping<\/strong> \u2014 automated on\/off on KF and ISO-K lines under PLC control.<\/li>\n<\/ul>\n<p>\u76f8\u95dc\u7522\u54c1\uff1a\u6b64\u95a5\u9580\u7684\u624b\u52d5\u7248\u672c\u662f\u6211\u5011\u7684 <a href=\"https:\/\/ballvalves.tw\/zh\/%e7%94%a2%e5%93%81\/%e6%89%8b%e5%8b%95%e7%9c%9f%e7%a9%ba%e9%96%a5\/\">\u624b\u52d5\u771f\u7a7a\u95a5<\/a>; \uff1b\u95dc\u65bc\u5728\u5169\u689d\u771f\u7a7a\u7ba1\u7dda\u4e4b\u9593\u9032\u884c\u5206\u6d41\uff0c\u8acb\u53c3\u95b1 <a href=\"https:\/\/ballvalves.tw\/zh\/%e7%94%a2%e5%93%81\/3-%e9%80%9a%e7%9c%9f%e7%a9%ba%e7%90%83%e9%96%a5\/\">\u4e09\u901a\u771f\u7a7a\u7403\u95a5<\/a>. KF\/NW \u5b9a\u4f4d\u74b0\u662f <a href=\"https:\/\/ballvalves.tw\/zh\/%e7%94%a2%e5%93%81\/kf-nw-%e7%9c%9f%e7%a9%ba%e5%ae%9a%e5%bf%83%e7%92%b0\/\">\u9019\u88e1<\/a>.<\/p>\n<h2>\u5e38\u898b\u554f\u984c<\/h2>\n<h3>\u6709\u54ea\u4e9b\u6cd5\u862d\u5c3a\u5bf8\u53ef\u4f9b\u9078\u64c7\uff1f<\/h3>\n<p>NW50 (ISO-KF \/ KF50) clamp flange at 2\u2033 (V-2VN), and ISO-K in ISO80 (DN80, 3\u2033) and ISO100 (DN100, 4\u2033) (V-2BN-ISOK). Each clamps straight into its standard line \u2014 no adapter needed.<\/p>\n<h3>What is the difference between the NW50 KF version and the ISO-K version?<\/h3>\n<p>The valve, seats, actuator and ISO 5211 mounting are the same. The difference is the flange: KF is a small clamp flange that seals with one clamp and a centring ring, used for the 2\u2033 size; ISO-K is the larger flange standard used for the 3\u2033 and 4\u2033 sizes. Choose by the flange already on your line.<\/p>\n<h3>\u96d9\u4f5c\u7528\u9084\u662f\u5f48\u7c27\u5fa9\u4f4d\u2014\u2014\u6211\u8a72\u9078\u64c7\u54ea\u4e00\u7a2e\uff1f<\/h3>\n<p>\u96d9\u4f5c\u7528\u5f0f\u95a5\u9580\u5229\u7528\u6c23\u58d3\u958b\u555f\uff0c\u4e5f\u5229\u7528\u6c23\u58d3\u95dc\u9589\uff0c\u4e14\u82e5\u6c23\u6e90\u4e2d\u65b7\uff0c\u95a5\u9580\u6703\u4fdd\u6301\u5728\u6700\u5f8c\u4e00\u500b\u4f4d\u7f6e\u3002\u5f48\u7c27\u56de\u4f4d\u5f0f\u95a5\u9580\u5247\u662f\u4e00\u7aef\u5229\u7528\u6c23\u58d3\uff0c\u53e6\u4e00\u7aef\u4f9d\u9760\u5f48\u7c27\uff0c\u56e0\u6b64\u7576\u6c23\u58d3\u4e2d\u65b7\u6642\uff0c\u95a5\u9580\u6703\u79fb\u52d5\u81f3\u9810\u8a2d\u4f4d\u7f6e\u3002\u8acb\u544a\u77e5\u8a72\u4f4d\u7f6e\u61c9\u70ba\u958b\u555f\u6216\u95dc\u9589\u72c0\u614b\uff0c\u6211\u5011\u5c07\u4f9d\u6b64\u9032\u884c\u88fd\u9020\u3002.<\/p>\n<h3>\u5de5\u4f5c\u6eab\u5ea6\u7bc4\u570d\u70ba\u4f55\uff1f<\/h3>\n<p>Valve \u221220 \u00b0C to +180 \u00b0C, set by the PTFE seats. Actuator \u221220 \u00b0C to +80 \u00b0C.<\/p>\n<h3>\u57f7\u884c\u5668\u9700\u8981\u652f\u67b6\u55ce\uff1f<\/h3>\n<p>\u4e0d\u3002\u95a5\u9ad4\u914d\u5099\u4e86\u7b26\u5408 ISO 5211 \u6a19\u6e96\u7684\u5b89\u88dd\u588a\u7247\uff0c\u56e0\u6b64\u57f7\u884c\u5668\u53ef\u76f4\u63a5\u9396\u4e0a\u2014\u2014\u7121\u9700\u4efb\u4f55\u6a5f\u52a0\u5de5\uff0c\u4e5f\u7121\u9700\u5c0d\u4f4d\u3002.<\/p>\n<h3>\u6211\u53ef\u4ee5\u52a0\u88dd\u96fb\u78c1\u95a5\u6216\u9650\u4f4d\u958b\u95dc\u55ce\uff1f<\/h3>\n<p>\u662f\u7684\u3002\u8a72\u57f7\u884c\u5668\u53ef\u642d\u914d\u96fb\u78c1\u95a5\u9032\u884c\u63a7\u5236\u3001\u9650\u4f4d\u958b\u95dc\u76d2\u9032\u884c\u4f4d\u7f6e\u56de\u994b\uff0c\u4ee5\u53ca\u5b9a\u4f4d\u5668\u9032\u884c\u8abf\u88fd\u64cd\u4f5c\u2014\u2014\u8acb\u5728\u7d22\u53d6\u5831\u50f9\u6642\u544a\u77e5\u6211\u5011\u60a8\u7684\u63a7\u5236\u914d\u7f6e\u3002.<\/p>\n<h3>\u662f\u5426\u6709\u6700\u4f4e\u8a02\u8cfc\u91cf\uff1f<\/h3>\n<p>\u4e0d\uff0c\u6211\u5011\u6c92\u6709\u6700\u4f4e\u8a02\u8cfc\u91cf\u3002\u8acb\u544a\u8a34\u6211\u5011\u60a8\u7684\u9700\u6c42\uff0c\u6211\u5011\u5c07\u70ba\u60a8\u5831\u50f9\u3002.<\/p>","protected":false},"excerpt":{"rendered":"<p>A vacuum rated ball valve with a pneumatic actuator: two-piece 316 stainless body, full port, PTFE seats, ISO 5211 direct mount. Choose NW50 (ISO-KF \/ KF50) clamp ends at 2\u2033 or ISO-K flanges at DN80 (3\u2033) and DN100 (4\u2033). The rack-and-pinion actuator, double acting or spring return, opens and closes the line on a signal. For fore-line and pump isolation, not as a high-vacuum chamber gate.<\/p>\n<p style=\"font-size: 14px;color: #666666\">ISO 9001 \u00b7 CE \u00b7 Manufacturer since 1999 \u00b7 Made in Taiwan<\/p>","protected":false},"featured_media":5163,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[78],"product_cat":[68],"product_tag":[],"class_list":["post-3850","product","type-product","status-publish","has-post-thumbnail","product_brand-yzng-trong","product_cat-vacuum-valve","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","taxable","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/ballvalves.tw\/zh\/wp-json\/wp\/v2\/product\/3850","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ballvalves.tw\/zh\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ballvalves.tw\/zh\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ballvalves.tw\/zh\/wp-json\/wp\/v2\/media\/5163"}],"wp:attachment":[{"href":"https:\/\/ballvalves.tw\/zh\/wp-json\/wp\/v2\/media?parent=3850"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ballvalves.tw\/zh\/wp-json\/wp\/v2\/product_brand?post=3850"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ballvalves.tw\/zh\/wp-json\/wp\/v2\/product_cat?post=3850"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ballvalves.tw\/zh\/wp-json\/wp\/v2\/product_tag?post=3850"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}