{"id":3859,"date":"2025-10-17T09:30:16","date_gmt":"2025-10-17T01:30:16","guid":{"rendered":"https:\/\/ballvalves.tw\/?post_type=product&#038;p=3859"},"modified":"2026-07-17T08:47:40","modified_gmt":"2026-07-17T00:47:40","slug":"%e7%9b%ae%e7%9b%9b%e3%82%8a%e4%bb%98%e3%81%8d%e3%83%8f%e3%83%b3%e3%83%89%e3%83%ab","status":"publish","type":"product","link":"https:\/\/ballvalves.tw\/ja\/product\/graduated-handle\/","title":{"rendered":"\u76ee\u76db\u308a\u4ed8\u304d\u30dc\u30fc\u30eb\u30d0\u30eb\u30d6\u30cf\u30f3\u30c9\u30eb \u2014 0\uff5e90\u00b0\u306e\u624b\u52d5\u6d41\u91cf\u5236\u5fa1"},"content":{"rendered":"<h2>\u88fd\u54c1\u8aac\u660e<\/h2>\n<p>A standard ball valve is built for all-or-nothing flow. Fit this <strong>\u76ee\u76db\u308a\u4ed8\u304d\u30cf\u30f3\u30c9\u30eb<\/strong> and it becomes a simple <strong>manual flow control ball valve<\/strong>: a scale plate marked from 0\u00b0 to 90\u00b0 in 10\u00b0 increments sits under the handle, and a locking pin secures the handle at the notch you choose \u2014 30\u00b0, 50\u00b0, or any other step.<\/p>\n<p>For simple throttling jobs, this is a far cheaper route than an automated control valve \u2014 one 304 stainless steel accessory instead of an actuator, positioner, and wiring.<\/p>\n<h2>How the Locking Pin Works<\/h2>\n<ul>\n<li><strong>Set:<\/strong> turn the handle to the angle you need and secure the locking pin in the matching notch on the graduated plate.<\/li>\n<li><strong>Hold:<\/strong> with the pin engaged, the handle resists pipeline vibration and flow-induced movement in normal service \u2014 changing the position takes a deliberate release of the pin.<\/li>\n<li><strong>Repeat:<\/strong> operators can note a setting (&#8220;notch 3&#8221;) and return the valve to exactly the same flow after maintenance or flushing.<\/li>\n<\/ul>\n<h2>\u4e3b\u306a\u4ed5\u69d8<\/h2>\n<table style=\"width:100%;border-collapse:collapse\">\n<tbody>\n<tr>\n<th style=\"border:1px solid #ddd;padding:8px;text-align:left;width:38%\">\u7d20\u6750<\/th>\n<td style=\"border:1px solid #ddd;padding:8px\">ASTM 304 \u30b9\u30c6\u30f3\u30ec\u30b9\u92fc<\/td>\n<\/tr>\n<tr>\n<th style=\"border:1px solid #ddd;padding:8px;text-align:left\">Scale<\/th>\n<td style=\"border:1px solid #ddd;padding:8px\">0\u00b0 \u2013 90\u00b0, in 10\u00b0 increments<\/td>\n<\/tr>\n<tr>\n<th style=\"border:1px solid #ddd;padding:8px;text-align:left\">Mechanism<\/th>\n<td style=\"border:1px solid #ddd;padding:8px\">Locking pin on a graduated plate<\/td>\n<\/tr>\n<tr>\n<th style=\"border:1px solid #ddd;padding:8px;text-align:left\">\u5bfe\u5fdc\u30b5\u30a4\u30ba<\/th>\n<td style=\"border:1px solid #ddd;padding:8px\">Our ball valve series \u2014 tell us your valve model when ordering<\/td>\n<\/tr>\n<tr>\n<th style=\"border:1px solid #ddd;padding:8px;text-align:left\">SKU<\/th>\n<td style=\"border:1px solid #ddd;padding:8px\">HG-304<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Ball Valve + Graduated Handle vs. Control Valve<\/h2>\n<p>This handle suits <strong>manual balancing<\/strong>: jobs where someone sets a flow rate once and the system holds it. If your process needs continuous automatic adjustment, that is control-valve territory \u2014 but for filling, cooling, or mixing lines that just need a repeatable setting, the graduated handle does the job at a fraction of the cost.<\/p>\n<h2>\u4f7f\u7528\u5834\u6240<\/h2>\n<ul>\n<li><strong>HVAC balancing<\/strong> \u2014 regulating hot and cold water flow to coils.<\/li>\n<li><strong>Mixing lines<\/strong> \u2014 manually setting the ratio between two fluids.<\/li>\n<li><strong>Process control<\/strong> \u2014 holding a constant flow rate for filling or cooling.<\/li>\n<\/ul>\n<h2>\u3069\u306e\u30cf\u30f3\u30c9\u30eb\u304c\u5fc5\u8981\u3067\u3059\u304b\uff1f<\/h2>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #ddd;padding:8px;text-align:left\">\u30cf\u30f3\u30c9\u30eb<\/th>\n<th style=\"border:1px solid #ddd;padding:8px;text-align:left\">\u3044\u3064\u9078\u3076\u304b<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\"><strong>Graduated handle (this page)<\/strong><\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">You need to throttle flow and lock the valve at a repeatable position.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\"><a href=\"https:\/\/ballvalves.tw\/ja\/%e8%a3%bd%e5%93%81\/%e3%83%ad%e3%83%83%e3%82%af%e6%a9%9f%e8%83%bd%e4%bb%98%e3%81%8d%e3%83%8f%e3%83%b3%e3%83%89%e3%83%ab\/\">\u30ed\u30c3\u30af\u6a5f\u80fd\u4ed8\u304d\u30cf\u30f3\u30c9\u30eb<\/a><\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">\u30ed\u30c3\u30af\u30a2\u30a6\u30c8\uff0f\u30bf\u30b0\u30a2\u30a6\u30c8\u306e\u305f\u3081\u3001\u30d0\u30eb\u30d6\u306b\u306f\u5357\u4eac\u9320\u3092\u304b\u3051\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\"><a href=\"https:\/\/ballvalves.tw\/ja\/%e8%a3%bd%e5%93%81\/%e3%83%9c%e3%83%bc%e3%83%ab%e3%83%90%e3%83%ab%e3%83%96%e7%94%a8%e3%83%93%e3%83%8b%e3%83%bc%e3%83%ab%e3%82%b3%e3%83%bc%e3%83%86%e3%82%a3%e3%83%b3%e3%82%b0%e6%a5%95%e5%86%86%e3%83%8f%e3%83%b3%e3%83%89\/\">Oval handle<\/a><\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">You want a comfortable, glove-friendly grip for frequent operation, or a replacement handle.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\"><a href=\"https:\/\/ballvalves.tw\/ja\/%e8%a3%bd%e5%93%81\/%e5%bb%b6%e9%95%b7%e3%83%8f%e3%83%b3%e3%83%89%e3%83%ab\/\">Extended handle<\/a><\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">The valve sits on insulated pipe and the grip has to clear the insulation.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\"><a href=\"https:\/\/ballvalves.tw\/ja\/%e8%a3%bd%e5%93%81\/%e3%83%90%e3%82%bf%e3%83%95%e3%83%a9%e3%82%a4%e3%83%8f%e3%83%b3%e3%83%89%e3%83%ab\/\">Butterfly handle<\/a><\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">You prefer a compact stainless T-shaped grip.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<h3>Can a ball valve really be used for flow control?<\/h3>\n<p>For simple manual throttling, yes. The graduated plate lets you set a partial opening and secure it with the locking pin. For processes that need continuous, automatic adjustment, use a dedicated control valve \u2014 this handle is the low-cost answer for set-and-hold applications.<\/p>\n<h3>What are the scale increments?<\/h3>\n<p>The plate is marked from 0\u00b0 to 90\u00b0 in 10\u00b0 increments, so the valve locks at any of the ten positions.<\/p>\n<h3>\u3069\u306e\u30d0\u30eb\u30d6\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u307e\u3059\u304b\uff1f<\/h3>\n<p>Our own ball valve series. The handle is made to match our valve stems, so we do not guarantee fit on other brands&#8217; valves \u2014 include your valve model when ordering.<\/p>\n<h3>Is this the same as a memory stop?<\/h3>\n<p>It covers the same need and more. A memory stop limits the handle to one preset position; the graduated handle locks at any 10\u00b0 step and lets you return to a recorded setting whenever you want.<\/p>\n<h3>Will vibration shift the valve position?<\/h3>\n<p>The locking pin secures the handle in the plate notch, so the setting resists pipeline vibration and flow pressure in normal service. Changing the position takes a deliberate release of the pin by the operator.<\/p>\n<h3>\u4fa1\u683c\u3092\u78ba\u8a8d\u3059\u308b\u306b\u306f\u3069\u3046\u3059\u308c\u3070\u3088\u3044\u3067\u3059\u304b\uff1f<\/h3>\n<p>Send us the quantity and the valve model the handle is for. We reply to every inquiry within 24 hours.<\/p>\n<p><a href=\"https:\/\/ballvalves.tw\/ja\/%e3%82%b3%e3%83%b3%e3%82%bf%e3%82%af%e3%83%88\/\" style=\"display:inline-block;background:#c62828;color:#ffffff !important;font-size:16px;font-weight:700;padding:14px 26px;border-radius:6px;text-decoration:none\">\u304a\u898b\u7a4d\u308a\u4f9d\u983c \u2014 24\u6642\u9593\u4ee5\u5185\u306b\u8fd4\u4fe1\u3044\u305f\u3057\u307e\u3059 \u2192<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>A 304 stainless steel <strong>\u76ee\u76db\u308a\u4ed8\u304d\u30cf\u30f3\u30c9\u30eb<\/strong> that turns a standard on\/off ball valve into a <strong>manual flow control valve<\/strong> \u2014 set the opening anywhere from 0\u00b0 to 90\u00b0 in 10\u00b0 steps and secure it with the locking pin.<\/p>\n<p><strong>Fits our own ball valve series<\/strong> \u2014 tell us your valve model when ordering.<\/p>\n<p>ISO 9001\u30fbCE\u30fb1999\u5e74\u3088\u308a\u88fd\u9020<\/p>\n<p><a href=\"https:\/\/ballvalves.tw\/ja\/%e3%82%b3%e3%83%b3%e3%82%bf%e3%82%af%e3%83%88\/\" style=\"display:inline-block;background:#c62828;color:#ffffff !important;font-size:16px;font-weight:700;padding:14px 26px;border-radius:6px;text-decoration:none\">\u304a\u898b\u7a4d\u308a\u4f9d\u983c \u2014 24\u6642\u9593\u4ee5\u5185\u306b\u8fd4\u4fe1\u3044\u305f\u3057\u307e\u3059 \u2192<\/a><\/p>","protected":false},"featured_media":4003,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[78],"product_cat":[69],"product_tag":[],"class_list":["post-3859","product","type-product","status-publish","has-post-thumbnail","product_brand-yzng-trong","product_cat-accessories","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","taxable","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/ballvalves.tw\/ja\/wp-json\/wp\/v2\/product\/3859","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ballvalves.tw\/ja\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ballvalves.tw\/ja\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ballvalves.tw\/ja\/wp-json\/wp\/v2\/media\/4003"}],"wp:attachment":[{"href":"https:\/\/ballvalves.tw\/ja\/wp-json\/wp\/v2\/media?parent=3859"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ballvalves.tw\/ja\/wp-json\/wp\/v2\/product_brand?post=3859"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ballvalves.tw\/ja\/wp-json\/wp\/v2\/product_cat?post=3859"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ballvalves.tw\/ja\/wp-json\/wp\/v2\/product_tag?post=3859"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}