{"id":5730,"date":"2026-11-26T11:29:13","date_gmt":"2026-11-26T03:29:13","guid":{"rendered":"https:\/\/ballvalves.tw\/?p=5730"},"modified":"2026-11-26T11:29:13","modified_gmt":"2026-11-26T03:29:13","slug":"helium-leak-testing-valves","status":"publish","type":"post","link":"https:\/\/ballvalves.tw\/es\/helium-leak-testing-valves\/","title":{"rendered":"Helium Leak Testing for Vacuum-Rated Valves: Procedure, Leak Rate Units &amp; Acceptance Criteria"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><strong>Quick Summary:<\/strong> <strong>Helium leak testing<\/strong> uses a helium mass spectrometer leak detector (MSLD) to quantify microscopic gas leaks in vacuum-rated valves down to 10<sup>-9<\/sup> mbar\u00b7L\/s (10<sup>-10<\/sup> Pa\u00b7m\u00b3\/s) and beyond. Unlike a standard <strong>bubble leak test<\/strong>\u2014which stops around 10<sup>-3<\/sup> to 10<sup>-4<\/sup> mbar\u00b7L\/s\u2014helium testing verifies both body (shell) integrity and <strong>valve seat leakage<\/strong> for rough-to-high vacuum applications such as <strong>KF ball valve<\/strong> forelines and pumping systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If you are sourcing a <strong>vacuum rated ball valve<\/strong> for a pumping foreline, coating system, degassing chamber, or high-purity gas line, &#8220;100% leak tested&#8221; on a brochure does not tell you enough. Standard industrial valve leak tests are built for positive pressure, not vacuum. Knowing how a <strong>helium mass spectrometer leak test<\/strong> works\u2014and how to write realistic <strong>helium leak test acceptance criteria<\/strong> on your RFQ\u2014prevents vacuum pump-down failures, disputed inspections, and unnecessary cost.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><em>Evaluating whether a ball valve fits your vacuum pressure range first? Read our guide on <a href=\"https:\/\/ballvalves.tw\/es\/vacuum-ball-valve\/\">using ball valves in vacuum systems<\/a> for rough, medium, and high-vacuum selection criteria.<\/em><\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Why Standard Bubble Leak Tests Are Not Enough for Vacuum-Rated Valves<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>bubble leak test<\/strong> (air-under-water or soap-solution testing) is reliable for general industrial shut-off valves operating under positive pressure, but it cannot detect molecular-level leaks that degrade a vacuum system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">During a bubble leak test, the valve is pressurized with air or nitrogen and submerged in water. An operator watches for escaping bubbles. Even under careful inspection, the practical sensitivity limit of a bubble test is roughly <strong>10<sup>-3<\/sup> to 10<sup>-4<\/sup> mbar\u00b7L\/s<\/strong>. A leak smaller than that produces no visible bubbles\u2014yet under vacuum, atmospheric air continuously seeps inward through micro-paths in castings, threaded joints, or stem packings, preventing the chamber from reaching base pressure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Comparison of Common Vacuum Leak Testing Methods<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Testing Method<\/th><th>Typical Sensitivity Limit (mbar\u00b7L\/s)<\/th><th>Typical Sensitivity Limit (Pa\u00b7m\u00b3\/s)<\/th><th>Best Suited For<\/th><th>Key Limitation<\/th><\/tr><\/thead><tbody><tr><td><strong>Bubble Leak Test<\/strong> (Air-Under-Water)<\/td><td>10<sup>-3<\/sup> to 10<sup>-4<\/sup><\/td><td>10<sup>-4<\/sup> to 10<sup>-5<\/sup><\/td><td>Standard industrial water, oil, gas &amp; compressed air valves<\/td><td>Operator-dependent; cannot detect fine vacuum leaks<\/td><\/tr><tr><td><strong>Pressure Decay \/ Vacuum Decay<\/strong><\/td><td>10<sup>-2<\/sup> to 10<sup>-4<\/sup><\/td><td>10<sup>-3<\/sup> to 10<sup>-5<\/sup><\/td><td>Automated gross-leak screening on production lines<\/td><td>Affected by temperature shifts and outgassing; does not pinpoint leak location<\/td><\/tr><tr><td><strong>Helium Sniffer Mode<\/strong> (Detector Probe)<\/td><td>10<sup>-5<\/sup> to 10<sup>-6<\/sup><\/td><td>10<sup>-6<\/sup> to 10<sup>-7<\/sup><\/td><td>Large pressurized assemblies or field-installed piping<\/td><td>Limited by ambient background helium (~5 ppm in air)<\/td><\/tr><tr><td><strong>Helium Vacuum Mode<\/strong> (Mass Spectrometer)<\/td><td><strong>10<sup>-8<\/sup> to 10<sup>-11<\/sup><\/strong><\/td><td><strong>10<sup>-9<\/sup> to 10<sup>-12<\/sup><\/strong><\/td><td><strong>Vacuum-rated ball valves (KF \/ ISO-K), forelines &amp; high-purity lines<\/strong><\/td><td>Higher test time and cost; requires clean, dry test parts<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img fetchpriority=\"high\" decoding=\"async\" width=\"2400\" height=\"1350\" src=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/bubble-test-vs-helium-leak-testing-scale.webp\" alt=\"Valve leak testing sensitivity comparison scale from bubble leak test to vacuum-mode helium mass spectrometer in mbar\u00b7L\/s and Pa\u00b7m\u00b3\/s\" class=\"wp-image-5727\" srcset=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/bubble-test-vs-helium-leak-testing-scale.webp 2400w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/bubble-test-vs-helium-leak-testing-scale-300x169.webp 300w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/bubble-test-vs-helium-leak-testing-scale-1024x576.webp 1024w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/bubble-test-vs-helium-leak-testing-scale-768x432.webp 768w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/bubble-test-vs-helium-leak-testing-scale-1536x864.webp 1536w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/bubble-test-vs-helium-leak-testing-scale-2048x1152.webp 2048w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/bubble-test-vs-helium-leak-testing-scale-18x10.webp 18w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/bubble-test-vs-helium-leak-testing-scale-600x338.webp 600w\" sizes=\"(max-width: 2400px) 100vw, 2400px\" \/><figcaption class=\"wp-element-caption\">Sensitivity comparison across valve leak testing methods, aligning <code>mbar\u00b7L\/s<\/code> y <code>Pa\u00b7m\u00b3\/s<\/code> leak rate units.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Helium Leak Test Procedure for Vacuum-Rated Ball Valves<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>helium leak test procedure<\/strong> for a vacuum valve uses helium as a tracer gas because helium atoms are tiny (atomic mass 4), inert, non-toxic, and scarce in ambient air. In a factory quality-control setup, <strong>vacuum mode<\/strong> (the tracer probe \/ spray method, aligned with <strong>ASTM E498<\/strong> y <strong>ISO 20485<\/strong>) is the standard way to verify vacuum-rated valves.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Step-by-Step Vacuum Mode Procedure<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Pre-Test Preparation &amp; Drying:<\/strong> The valve must be clean and dry. Residual moisture or cutting oil can temporarily plug microscopic leak paths and mask defects, or cause slow outgassing that delays pump-down.<\/li>\n\n\n\n<li><strong>Flange Mounting to the Leak Detector:<\/strong> The valve (such as a <strong>KF ball valve<\/strong> or ISO-K flanged valve) is coupled directly to the test port of a <strong>helium mass spectrometer leak detector<\/strong> using clean centering rings, elastomer O-rings, and clamps. Unused ports are sealed with vacuum blank flanges.<\/li>\n\n\n\n<li><strong>Evacuation &amp; Background Stabilization:<\/strong> The detector&#8217;s vacuum pump evacuates the interior of the valve until the system reaches test pressure and the background helium signal stabilizes.<\/li>\n\n\n\n<li><strong>Helium Spraying (Tracer Probe):<\/strong> While monitoring the spectrometer readout, the technician applies a controlled stream of helium gas around potential external leak paths\u2014working from top to bottom (since helium rises):\n<ul class=\"wp-block-list\">\n<li>Stem seal \/ packing gland area<\/li>\n\n\n\n<li>Body joints and end-cap seals (on 2-piece and 3-piece designs)<\/li>\n\n\n\n<li>Welds and flange-to-body transitions<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Reading &amp; Verification:<\/strong> If a leak path exists, helium enters the evacuated valve body, reaches the mass spectrometer analyzer cell, and registers as a quantitative <strong>helium leak rate<\/strong> on the instrument display.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"725\" height=\"805\" src=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/kf-vacuum-ball-valve-helium-leak-testing.webp\" alt=\"Yzng Trong stainless steel KF vacuum ball valve assembly mounted on an in-house helium mass spectrometer leak detector in vacuum mode\" class=\"wp-image-5728\" srcset=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/kf-vacuum-ball-valve-helium-leak-testing.webp 725w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/kf-vacuum-ball-valve-helium-leak-testing-270x300.webp 270w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/kf-vacuum-ball-valve-helium-leak-testing-11x12.webp 11w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/kf-vacuum-ball-valve-helium-leak-testing-600x666.webp 600w\" sizes=\"(max-width: 725px) 100vw, 725px\" \/><figcaption class=\"wp-element-caption\">In-house vacuum-mode helium mass spectrometer leak testing setup on stainless steel KF vacuum ball valves at Yzng Trong&#8217;s Taichung facility.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Shell (Envelope) Leak vs. Valve Seat Leakage Test<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">When specifying <strong>valve leak testing<\/strong>, one of the most common RFQ mistakes is asking for a helium leak rate without stating <strong>which boundary<\/strong> is being tested. A valve has two distinct sealing boundaries, and they behave differently under vacuum.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"2400\" height=\"1350\" src=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/shell-leak-vs-seat-leak-vacuum-ball-valve.webp\" alt=\"Diagram comparing shell envelope leak test vs across-the-seat valve seat leakage test on a vacuum-rated ball valve\" class=\"wp-image-5729\" srcset=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/shell-leak-vs-seat-leak-vacuum-ball-valve.webp 2400w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/shell-leak-vs-seat-leak-vacuum-ball-valve-300x169.webp 300w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/shell-leak-vs-seat-leak-vacuum-ball-valve-1024x576.webp 1024w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/shell-leak-vs-seat-leak-vacuum-ball-valve-768x432.webp 768w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/shell-leak-vs-seat-leak-vacuum-ball-valve-1536x864.webp 1536w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/shell-leak-vs-seat-leak-vacuum-ball-valve-2048x1152.webp 2048w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/shell-leak-vs-seat-leak-vacuum-ball-valve-18x10.webp 18w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/shell-leak-vs-seat-leak-vacuum-ball-valve-600x338.webp 600w\" sizes=\"(max-width: 2400px) 100vw, 2400px\" \/><figcaption class=\"wp-element-caption\">Shell (external envelope) leak testing with the valve open versus across-the-seat internal leakage testing with the valve closed.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Test Boundary<\/th><th>What It Measures<\/th><th>Valve Position During Test<\/th><th>Primary Leak Paths Checked<\/th><\/tr><\/thead><tbody><tr><td><strong>Shell \/ Envelope Leak Test<\/strong> (External)<\/td><td>Leakage from the outside atmosphere <em>en<\/em> the evacuated valve interior<\/td><td>Open or half-open (ports blanked off)<\/td><td>Casting porosity, body-to-end-cap gaskets, welds, and stem O-rings\/packing<\/td><\/tr><tr><td><strong>Valve Seat Leakage Test<\/strong> (Across-the-Seat \/ Internal)<\/td><td>Leakage <em>across<\/em> the closed ball and PTFE seat from one port to the other<\/td><td>Fully closed (one side evacuated, opposite side exposed to helium)<\/td><td>Ball surface finish, PTFE seat contact, seat spring\/compression integrity<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Why This Distinction Matters for Ball Valves<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Elastomer &amp; PTFE Reality:<\/strong> Unlike metal-sealed ultra-high-vacuum (UHV) gate valves, <strong>vacuum rated ball valves<\/strong> rely on precision-machined PTFE seats and FKM\/Viton stem O-rings. They excel in rough-to-high vacuum roughing lines, forelines, and particle-bearing exhaust lines because the quarter-turn ball wipes the seat clean.<\/li>\n\n\n\n<li><strong>Permeation vs. Real Leaks:<\/strong> Over extended exposure, helium can slowly permeate through soft polymers (PTFE and elastomer O-rings). A proper <strong>helium leak test procedure<\/strong> distinguishes between an immediate spike (a real leak path) and a slow, delayed rise (gas permeation through seals).<\/li>\n\n\n\n<li><strong>Always Specify Both if Needed:<\/strong> If your process requires tight isolation across the closed ball (not just atmospheric tightness), explicitly list both the <strong>shell leak rate<\/strong> y el <strong>across-the-seat leak rate<\/strong> on your purchase specification.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Understanding Leak Rate Units (<code>Pa\u00b7m\u00b3\/s<\/code> vs. <code>mbar\u00b7L\/s<\/code> vs. <code>atm\u00b7cc\/s<\/code>)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Engineers across Asia, Europe, and North America often use different <strong>leak rate units<\/strong>, which can cause a 10\u00d7 misreading during RFQ reviews if units are not converted accurately.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A vacuum leak rate measures gas throughput (Q = pressure \u00d7 volume \/ time). The most important conversion to remember is:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1 Pa\u00b7m\u00b3\/s = 10 mbar\u00b7L\/s \u2248 9.87 atm\u00b7cc\/s (std cc\/s)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Conversely:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1 mbar\u00b7L\/s = 0.1 Pa\u00b7m\u00b3\/s<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Quick Leak Rate Unit Conversion Reference<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Pa\u00b7m\u00b3\/s (SI \/ Common on Asian &amp; ISO Detectors)<\/th><th>mbar\u00b7L\/s (Common in Europe)<\/th><th>atm\u00b7cc\/s or std cc\/s (Common in US)<\/th><th>Practical Vacuum Context<\/th><\/tr><\/thead><tbody><tr><td>1.0 \u00d7 10<sup>-4<\/sup><\/td><td>1.0 \u00d7 10<sup>-3<\/sup><\/td><td>~9.9 \u00d7 10<sup>-4<\/sup><\/td><td>Upper edge of visible bubble leak test<\/td><\/tr><tr><td>1.0 \u00d7 10<sup>-7<\/sup><\/td><td>1.0 \u00d7 10<sup>-6<\/sup><\/td><td>~9.9 \u00d7 10<sup>-7<\/sup><\/td><td>Commercial \/ rough-to-medium vacuum valve tier<\/td><\/tr><tr><td>1.0 \u00d7 10<sup>-8<\/sup><\/td><td>1.0 \u00d7 10<sup>-7<\/sup><\/td><td>~9.9 \u00d7 10<sup>-8<\/sup><\/td><td>Fine vacuum isolation &amp; process lines<\/td><\/tr><tr><td>1.0 \u00d7 10<sup>-9<\/sup><\/td><td>1.0 \u00d7 10<sup>-8<\/sup><\/td><td>~9.9 \u00d7 10<sup>-9<\/sup><\/td><td>High-vacuum <strong>KF ball valve<\/strong> \/ ISO-K foreline grade<\/td><\/tr><tr><td>1.0 \u00d7 10<sup>-10<\/sup><\/td><td>1.0 \u00d7 10<sup>-9<\/sup><\/td><td>~9.9 \u00d7 10<sup>-10<\/sup><\/td><td>Tight high-vacuum elastomer\/PTFE assembly verification<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Engineering Tip:<\/strong> Because <code>mbar\u00b7L\/s<\/code>, <code>Torr\u00b7L\/s<\/code>y <code>atm\u00b7cc\/s<\/code> are within ~1\u201325% of each other, buyers sometimes treat them loosely\u2014but <strong><code>Pa\u00b7m\u00b3\/s<\/code> is 10 times larger per numerical unit than <code>mbar\u00b7L\/s<\/code><\/strong>. For example, 1.0 \u00d7 10<sup>-9<\/sup> Pa\u00b7m\u00b3\/s equals 1.0 \u00d7 10<sup>-8<\/sup> mbar\u00b7L\/s. Always check the unit printed on the test certificate.<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Setting Realistic Helium Leak Test Acceptance Criteria (And Avoiding Common RFQ Mistakes)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">When preparing a technical specification or RFQ for vacuum-rated valves, avoid these three pitfalls:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Never Write &#8220;Zero Leakage&#8221;:<\/strong> In vacuum physics, zero leakage is unmeasurable. Every <strong>helium leak test standard<\/strong> (such as ASTM E498 or ISO 20485) requires a defined numerical upper threshold\u2014for example, \u2264 1.0 \u00d7 10<sup>-8<\/sup> mbar\u00b7L\/s or \u2264 1.0 \u00d7 10<sup>-9<\/sup> Pa\u00b7m\u00b3\/s depending on your system requirements.<\/li>\n\n\n\n<li><strong>Do Not Confuse Detector Sensitivity with Valve Specification:<\/strong> A helium mass spectrometer may be capable of reading down to 10<sup>-11<\/sup> mbar\u00b7L\/s, but that is the <em>instrument&#8217;s<\/em> lower limit, not automatically the guaranteed leak rate of a PTFE-seated ball valve across every operating cycle.<\/li>\n\n\n\n<li><strong>Clarify Whether Helium Testing Is Required on Your Order:<\/strong> Standard industrial production valves undergo 100% pressure\/air leak testing before shipment. Because vacuum-mode helium mass spectrometer testing requires dedicated setup, pump-down time, and dry handling, <strong>in-house helium leak testing at Yzng Trong is offered as an optional, quoted verification service<\/strong> for vacuum-rated and critical orders rather than applied automatically to standard commercial valves. Specifying it upfront ensures accurate pricing, lead time, and test documentation.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">RFQ Checklist: What to Include When Requesting Helium-Tested Vacuum Ball Valves<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">To get an accurate quotation and confirm test feasibility without back-and-forth delays, include these 7 items in your inquiry:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>1. Valve Configuration:<\/strong> 2-way or 3-way (L-port \/ T-port); manual handle or pneumatic actuator (Double Acting \/ Spring Return).<\/li>\n\n\n\n<li><strong>2. Connection &amp; Size:<\/strong> ISO-KF (e.g., KF16, KF25, KF40, KF50) or ISO-K flange size, or weld\/threaded ends. <em>(Explore our <a href=\"https:\/\/ballvalves.tw\/es\/categoria-producto\/valvula-de-vacio\/\">KF &amp; ISO-K vacuum ball valves<\/a> or product catalog for available sizes.)<\/em><\/li>\n\n\n\n<li><strong>3. Operating Vacuum &amp; Pressure Range:<\/strong> Target base pressure and any positive overpressure or purge gas conditions.<\/li>\n\n\n\n<li><strong>4. Required Helium Leak Rate &amp; Unit:<\/strong> State both the number and the unit (e.g., mbar\u00b7L\/s or Pa\u00b7m\u00b3\/s).<\/li>\n\n\n\n<li><strong>5. Test Boundary:<\/strong> Shell (external envelope) leak only, or both shell leak and across-the-seat (<strong>valve seat leakage test<\/strong>).<\/li>\n\n\n\n<li><strong>6. Documentation Needed:<\/strong> Whether you require a batch verification or serialized <strong>Helium Leak Test Report<\/strong> and Material Test Report (MTR \/ EN 10204 3.1).<\/li>\n\n\n\n<li><strong>7. Quantity &amp; Target Lead Time:<\/strong> Prototype\/sample quantity or recurring OEM production schedule.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Need In-House Helium Leak Verification for Your Vacuum Ball Valve Project?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yzng Trong manufactures stainless steel ball valves, vacuum-flanged KF \/ ISO-K assemblies, and pneumatic\/electric actuation packages in-house in Taichung, Taiwan\u2014with <strong>optional in-house helium mass spectrometer leak testing<\/strong> available upon request for vacuum-rated orders.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Send your flange size, target leak rate, and quantity to <strong><a href=\"mailto:sales@ballvalves.tw\">sales@ballvalves.tw<\/a><\/strong> (or via our <a href=\"https:\/\/ballvalves.tw\/es\/pongase-en-contacto-con\/\">Contact \/ RFQ page<\/a>) and our engineering team will review your specification and reply with a quote.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Preguntas m\u00e1s frecuentes (FAQ)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">What is the difference between a bubble leak test and helium leak testing for valves?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>bubble leak test<\/strong> pressurizes a valve with air and submerges it in water to spot visible bubbles, reaching a sensitivity limit of roughly 10<sup>-3<\/sup> to 10<sup>-4<\/sup> mbar\u00b7L\/s. <strong>Helium leak testing<\/strong> uses a helium mass spectrometer under vacuum to quantify microscopic molecular leaks down to 10<sup>-8<\/sup> to 10<sup>-11<\/sup> mbar\u00b7L\/s\u2014millions of times more sensitive and essential for vacuum-rated valves.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is a typical helium leak rate for a KF vacuum ball valve?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Depending on valve grade, seat design, and elastomer stem seals, industrial <strong>KF ball valves<\/strong> are typically specified in the range of <strong>10<sup>-6<\/sup> to 10<sup>-9<\/sup> mbar\u00b7L\/s<\/strong> (roughly 10<sup>-7<\/sup> to 10<sup>-10<\/sup> Pa\u00b7m\u00b3\/s). Always confirm both the unit and whether the rating applies to shell leakage or across-the-seat leakage.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How do you convert <code>Pa\u00b7m\u00b3\/s<\/code> a <code>mbar\u00b7L\/s<\/code>?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Multiply the value in Pa\u00b7m\u00b3\/s by <strong>10<\/strong> to get mbar\u00b7L\/s. For example, 1.0 \u00d7 10<sup>-9<\/sup> Pa\u00b7m\u00b3\/s = 1.0 \u00d7 10<sup>-8<\/sup> mbar\u00b7L\/s. Conversely, divide mbar\u00b7L\/s by 10 to convert to Pa\u00b7m\u00b3\/s.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What standards apply to helium leak testing of valves?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Common reference standards include <strong>ASTM E498<\/strong> (vacuum-mode tracer probe testing using a mass spectrometer leak detector), <strong>ASTM E499<\/strong> (sniffer\/detector probe mode), and <strong>ISO 20485<\/strong> (tracer gas leak testing). For industrial fugitive emissions rather than vacuum tightness, <strong>ISO 15848-1<\/strong> is also frequently referenced.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Is every ball valve helium leak tested before shipment?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. Standard industrial ball valves are 100% pressure\/air leak tested at the factory. Because vacuum-mode helium mass spectrometer testing requires specialized vacuum setup and handling, it is offered as an <strong>optional, quoted test service<\/strong> for vacuum-rated KF\/ISO-K ball valves and projects that explicitly specify helium leak verification on the RFQ.<\/p>","protected":false},"excerpt":{"rendered":"<p>Quick Summary: Helium leak testing uses a helium mass spectrometer leak detector (MSLD) to quantify microscopic gas leaks in vacuum-rated valves down to 10-9 mbar\u00b7L\/s (10-10 Pa\u00b7m\u00b3\/s) and beyond. Unlike a standard bubble leak test\u2014which stops around 10-3 to 10-4 mbar\u00b7L\/s\u2014helium testing verifies both body (shell) integrity and valve seat leakage for rough-to-high vacuum applications [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":5727,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[],"class_list":["post-5730","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-how-to-guides-tutorials"],"_links":{"self":[{"href":"https:\/\/ballvalves.tw\/es\/wp-json\/wp\/v2\/posts\/5730","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ballvalves.tw\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ballvalves.tw\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ballvalves.tw\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/ballvalves.tw\/es\/wp-json\/wp\/v2\/comments?post=5730"}],"version-history":[{"count":1,"href":"https:\/\/ballvalves.tw\/es\/wp-json\/wp\/v2\/posts\/5730\/revisions"}],"predecessor-version":[{"id":5731,"href":"https:\/\/ballvalves.tw\/es\/wp-json\/wp\/v2\/posts\/5730\/revisions\/5731"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ballvalves.tw\/es\/wp-json\/wp\/v2\/media\/5727"}],"wp:attachment":[{"href":"https:\/\/ballvalves.tw\/es\/wp-json\/wp\/v2\/media?parent=5730"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ballvalves.tw\/es\/wp-json\/wp\/v2\/categories?post=5730"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ballvalves.tw\/es\/wp-json\/wp\/v2\/tags?post=5730"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}