{"id":3850,"date":"2025-10-17T09:24:34","date_gmt":"2025-10-17T01:24:34","guid":{"rendered":"https:\/\/ballvalves.tw\/?post_type=product&#038;p=3850"},"modified":"2026-09-12T01:47:47","modified_gmt":"2026-09-11T17:47:47","slug":"pneumatisches-vakuumventil","status":"publish","type":"product","link":"https:\/\/ballvalves.tw\/de\/product\/pneumatic-vacuum-valve\/","title":{"rendered":"Vacuum Rated Ball Valve, Pneumatic \u2013 NW50 KF (2\u2033), ISO-K DN80 \/ DN100, 316 Two-Piece (V-2VN \/ V-2BN-ISOK)"},"content":{"rendered":"<div style=\"display: flex;flex-wrap: wrap;align-items: stretch;gap: 12px;margin: 18px 0\"><a style=\"display: block;min-width: 230px;flex: 1 1 calc(33.333% - 8px);padding: 17px 19px;background: #f3f8fd;border: 1px solid #c7dcef;border-left: 5px solid #1261a0;border-radius: 9px;color: #17324d!important;text-decoration: none;cursor: pointer\" href=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/06\/V-2VN-Pneumatic-Vacuum-Ball-Valve.pdf\" target=\"_blank\" rel=\"noopener\"><span style=\"display: inline-block;margin-right: 10px;padding: 6px 9px;background: #1261a0;color: #ffffff!important;border-radius: 5px;font-size: 12px;font-weight: bold;letter-spacing: .5px\">PDF<\/span><strong style=\"color: #17324d!important;font-size: 17px\">V-2VN<\/strong><span style=\"display: block;margin-top: 10px;color: #5d7185!important;font-size: 13px\">NW50 ISO-KF (2\u2033) \u00b7 Dimension Sheet <strong style=\"color: #1261a0!important\">PDF herunterladen \u2193<\/strong><\/span><\/a><\/div>\n<p>This vacuum rated ball valve is a two-piece 316 stainless steel pneumatic ball valve built for vacuum lines. It comes with two end styles: NW50 (ISO-KF \/ KF50) clamp flanges at 2\u2033 (model V-2VN), or ISO-K flanges at ISO80 (DN80, 3\u2033) and ISO100 (DN100, 4\u2033) (model V-2BN-ISOK). Both share the same full-port body, PTFE seats and an ISO 5211 pad that takes a rack-and-pinion air actuator, double acting (DA) or spring return (SR), so the valve opens and closes on a signal instead of by hand.<\/p>\n<h2>Where This Vacuum Pump Isolation Valve Belongs in the System<\/h2>\n<p>A vacuum ball valve has a clear place in a vacuum system: on the pump side. Here is where this valve is used and what it does there.<\/p>\n<div>\n<table style=\"min-width: 700px;width: 100%;border-collapse: collapse\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #ddd;padding: 8px\">Position im System<\/th>\n<th style=\"border: 1px solid #ddd;padding: 8px\">What the valve does there<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\"><strong>Trennung von Vorbearbeitungs- und Schruppbearbeitungslinie<\/strong><\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Between the pump and the chamber, on the roughing or backing line: this is what a vacuum ball valve is for.<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\"><strong>Trennung der Vakuumpumpe<\/strong><\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Eine Pumpe aus dem Leitungsstrang ausschalten, damit sie gewartet oder ausgetauscht werden kann, ohne das gesamte System entl\u00fcften zu m\u00fcssen.<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\"><strong>Messger\u00e4t-Isolierung<\/strong><\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Schutz eines Vakuummessger\u00e4ts beim Abpumpen oder Entl\u00fcften.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"font-size: 13px;color: #666;margin: 6px 0 28px\">\u2190 Wischen Sie \u00fcber die Tabelle, um alle Spalten anzuzeigen \u2192<\/p>\n<p>For isolating a pump, a fore-line or a gauge, a ball valve is the straightforward, fast, full-bore answer, and with a pneumatic actuator it does that on a signal.<\/p>\n<h2>Wichtige technische Spezifikationen<\/h2>\n<div>\n<table style=\"width: 100%;border-collapse: collapse\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #ddd;padding: 8px\">Artikel<\/th>\n<th style=\"border: 1px solid #ddd;padding: 8px\">Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Typ<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Two-piece vacuum ball valve, pneumatically actuated (V-2VN \/ V-2BN-ISOK)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Material der Karosserie<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">ASTM A351 CF8M (Edelstahl 316)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Verbindung<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">NW50 (ISO-KF \/ KF50) clamp flange \u2014 2\u2033 (V-2VN)<br \/>\nISO-K vacuum flange \u2014 ISO80 (DN80, 3\u2033) or ISO100 (DN100, 4\u2033) (V-2BN-ISOK)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Hafen<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Full port on all sizes<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Sitz &amp; Dichtung<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">PTFE<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Betriebstemperatur<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Valve \u221220 \u00b0C to +180 \u00b0C \u00b7 Actuator \u221220 \u00b0C to +80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Stellantrieb<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Rack-and-pinion, aluminium alloy body, double acting (DA) or spring return (SR)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Luftzufuhr<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">4 \u2013 8 bar (ca. 58 \u2013 116 psi)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Befestigung des Stellantriebs<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">ISO 5211 \u2013 Der Antrieb wird direkt an das Ventil angeschraubt, ohne Halterung oder Kupplung<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Federr\u00fcckstellposition<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Normalerweise geschlossen oder normalerweise offen \u2013 bitte bei der Bestellung angeben<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Optionen<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Magnetventil, Endschalterkasten, Stellungsregler<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Service<\/td>\n<td style=\"border: 1px solid #ddd;padding: 8px\">Automatisierte Isolierung und Sequenzierung auf Vakuumleitungen<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Vacuum Rated Valve Design: Why a Pneumatic Ball Valve<\/h2>\n<ul>\n<li><strong>Geschwindigkeit:<\/strong> Vakuumabl\u00e4ufe sind zeitlich gesteuert. Bei einem Handventil ist der Bediener der Engpass; bei einem pneumatischen Stellantrieb ist dies nicht der Fall.<\/li>\n<li><strong>Direktmontage:<\/strong> Der Ventilk\u00f6rper ist mit einer ISO 5211-Auflage ausgestattet, sodass der Antrieb ohne Halterung, ohne Kupplung und ohne Ausrichtungsaufwand angeschraubt werden kann.<\/li>\n<li><strong>Federr\u00fcckstellung bei Luftverlust:<\/strong> Eine SR-Einheit bewegt sich bei Ausfall der Luftzufuhr an die von Ihnen angegebene Position. Teilen Sie uns bitte mit, ob diese Position offen oder geschlossen ist, und wir werden sie entsprechend ausf\u00fchren.<\/li>\n<li><strong>Mit voller Kraft voraus:<\/strong> Da nichts die Leitung verengt, geht keine Leitf\u00e4higkeit durch das Ventil verloren.<\/li>\n<li><strong>Edelstahl 316, PTFE-Sitze:<\/strong> a clean, corrosion-resistant combination for vacuum service.<\/li>\n<\/ul>\n<h2>Pneumatic Vacuum Valve Ends: NW50 KF or ISO-K<\/h2>\n<p><strong>NW50 (ISO-KF \/ KF50), 2\u2033 \u2014 V-2VN.<\/strong> The KF clamp flange seals with a single clamp and a centring ring, no bolts, so the valve connects straight into a standard KF line and opens tool-free for service. The dimension sheet above gives face-to-face length, height to actuator top, flange O.D. and tube O.D.<\/p>\n<p><strong>ISO-K ISO80 (DN80, 3\u2033) and ISO100 (DN100, 4\u2033) \u2014 V-2BN-ISOK.<\/strong> The ISO-K flange clamps straight into a standard ISO-K line, no adapter needed, for the larger fore-lines and pump connections where KF sizes run out.<\/p>\n<h2>Anwendungen<\/h2>\n<ul>\n<li><strong>Trennung der Vakuumpumpe<\/strong> \u2014 shutting a pump out of the line for service without venting the system.<\/li>\n<li><strong>Roughing and backing lines<\/strong> \u2014 isolating rotary-vane or scroll pumps from the chamber.<\/li>\n<li><strong>Freeze-drying systems<\/strong> \u2014 isolating the vacuum line between the freeze dryer and its pump.<\/li>\n<li><strong>Vacuum ovens<\/strong> \u2014 shutting off chamber vacuum before the pump is switched off.<\/li>\n<li><strong>Laboratory vacuum piping<\/strong> \u2014 automated on\/off on KF and ISO-K lines under PLC control.<\/li>\n<\/ul>\n<p>Siehe auch: Die handbet\u00e4tigte Version dieses Ventils ist unser <a href=\"https:\/\/ballvalves.tw\/de\/produkt\/manuelles-vakuumventil\/\">manuelles Vakuumventil<\/a>; Informationen zur Umleitung zwischen zwei Vakuumleitungen finden Sie unter <a href=\"https:\/\/ballvalves.tw\/de\/produkt\/3-wege-vakuumkugelhahn\/\">3-Wege-Vakuum-Kugelhahn<\/a>. KF\/NW-Zentrierringe sind <a href=\"https:\/\/ballvalves.tw\/de\/produkt\/kf-nw-vakuum-zentrierring\/\">hier<\/a>.<\/p>\n<h2>H\u00e4ufig gestellte Fragen<\/h2>\n<h3>Welche Flanschgr\u00f6\u00dfen sind erh\u00e4ltlich?<\/h3>\n<p>NW50 (ISO-KF \/ KF50) clamp flange at 2\u2033 (V-2VN), and ISO-K in ISO80 (DN80, 3\u2033) and ISO100 (DN100, 4\u2033) (V-2BN-ISOK). Each clamps straight into its standard line \u2014 no adapter needed.<\/p>\n<h3>What is the difference between the NW50 KF version and the ISO-K version?<\/h3>\n<p>The valve, seats, actuator and ISO 5211 mounting are the same. The difference is the flange: KF is a small clamp flange that seals with one clamp and a centring ring, used for the 2\u2033 size; ISO-K is the larger flange standard used for the 3\u2033 and 4\u2033 sizes. Choose by the flange already on your line.<\/p>\n<h3>Doppeltwirkend oder federr\u00fcckstellend \u2013 wof\u00fcr soll ich mich entscheiden?<\/h3>\n<p>Bei der doppeltwirkenden Ausf\u00fchrung wird zum \u00d6ffnen und Schlie\u00dfen Druckluft verwendet, und das Ventil beh\u00e4lt seine letzte Position bei, wenn die Druckluftzufuhr ausf\u00e4llt. Bei der federr\u00fcckstellenden Ausf\u00fchrung wird in eine Richtung Druckluft und in die andere Richtung eine Feder verwendet, sodass sich das Ventil bei Druckluftverlust in eine voreingestellte Position bewegt. Teilen Sie uns bitte mit, ob diese Position \u201eoffen\u201c oder \u201egeschlossen\u201c sein soll, und wir fertigen das Ventil entsprechend an.<\/p>\n<h3>Wie gro\u00df ist der Betriebstemperaturbereich?<\/h3>\n<p>Valve \u221220 \u00b0C to +180 \u00b0C, set by the PTFE seats. Actuator \u221220 \u00b0C to +80 \u00b0C.<\/p>\n<h3>Ben\u00f6tigt der Stellantrieb eine Halterung?<\/h3>\n<p>Nein. Der Ventilk\u00f6rper verf\u00fcgt \u00fcber eine Befestigungsfl\u00e4che nach ISO 5211, sodass der Antrieb direkt angeschraubt werden kann \u2013 es muss weder etwas bearbeitet noch ausgerichtet werden.<\/p>\n<h3>Kann ich ein Magnetventil oder einen Endschalter hinzuf\u00fcgen?<\/h3>\n<p>Ja. Der Stellantrieb l\u00e4sst sich mit einem Magnetventil zur Steuerung, einem Endschalterkasten zur Positionsr\u00fcckmeldung und einem Stellungsregler f\u00fcr den Modulationsbetrieb kombinieren \u2013 teilen Sie uns bei Ihrer Angebotsanfrage bitte Ihre Steuerungskonfiguration mit.<\/p>\n<h3>Gibt es eine Mindestbestellmenge?<\/h3>\n<p>Nein. Wir haben keine Mindestbestellmenge. Teilen Sie uns einfach mit, was Sie ben\u00f6tigen, und wir erstellen Ihnen ein Angebot.<\/p>","protected":false},"excerpt":{"rendered":"<p>A vacuum rated ball valve with a pneumatic actuator: two-piece 316 stainless body, full port, PTFE seats, ISO 5211 direct mount. Choose NW50 (ISO-KF \/ KF50) clamp ends at 2\u2033 or ISO-K flanges at DN80 (3\u2033) and DN100 (4\u2033). The rack-and-pinion actuator, double acting or spring return, opens and closes the line on a signal. For fore-line and pump isolation, not as a high-vacuum chamber gate.<\/p>\n<p style=\"font-size: 14px;color: #666666\">ISO 9001 \u00b7 CE \u00b7 Manufacturer since 1999 \u00b7 Made in Taiwan<\/p>","protected":false},"featured_media":5163,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[78],"product_cat":[68],"product_tag":[],"class_list":["post-3850","product","type-product","status-publish","has-post-thumbnail","product_brand-yzng-trong","product_cat-vacuum-valve","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","taxable","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/ballvalves.tw\/de\/wp-json\/wp\/v2\/product\/3850","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ballvalves.tw\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ballvalves.tw\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ballvalves.tw\/de\/wp-json\/wp\/v2\/media\/5163"}],"wp:attachment":[{"href":"https:\/\/ballvalves.tw\/de\/wp-json\/wp\/v2\/media?parent=3850"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ballvalves.tw\/de\/wp-json\/wp\/v2\/product_brand?post=3850"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ballvalves.tw\/de\/wp-json\/wp\/v2\/product_cat?post=3850"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ballvalves.tw\/de\/wp-json\/wp\/v2\/product_tag?post=3850"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}