{"id":3850,"date":"2025-10-17T09:24:34","date_gmt":"2025-10-17T01:24:34","guid":{"rendered":"https:\/\/ballvalves.tw\/?post_type=product&#038;p=3850"},"modified":"2026-07-14T18:03:37","modified_gmt":"2026-07-14T10:03:37","slug":"%d8%b5%d9%85%d8%a7%d9%85-%d8%aa%d9%81%d8%b1%d9%8a%d8%ba-%d9%87%d9%88%d8%a7%d8%a6%d9%8a","status":"publish","type":"product","link":"https:\/\/ballvalves.tw\/ar\/product\/pneumatic-vacuum-valve\/","title":{"rendered":"\u0635\u0645\u0627\u0645 \u0643\u0631\u0648\u064a \u0647\u0648\u0627\u0626\u064a \u064a\u0639\u0645\u0644 \u0628\u0627\u0644\u0641\u0631\u0627\u063a \u2013 \u0645\u0646 \u0627\u0644\u0641\u0648\u0644\u0627\u0630 \u0627\u0644\u0645\u0642\u0627\u0648\u0645 \u0644\u0644\u0635\u062f\u0623 316\u060c \u0634\u0641\u0629 ISO-K DN80 \/ DN100\u060c \u0641\u062a\u062d\u0629 \u0643\u0627\u0645\u0644\u0629"},"content":{"rendered":"<h2>\u0648\u0635\u0641 \u0627\u0644\u0645\u0646\u062a\u062c<\/h2>\n<p>A pneumatically actuated vacuum ball valve in 316 stainless steel, with an ISO-K flange that clamps straight into a standard ISO-K line \u2014 no adapter. The air actuator opens and closes it in a fraction of the time a hand-operated valve takes, which is the point: on a vacuum line, the valve is usually the slowest thing in the sequence.<\/p>\n<p>Available in ISO80 (DN80, 3\u2033) and ISO100 (DN100, 4\u2033).<\/p>\n<h2>Where This Valve Belongs \u2014 and Where It Does Not<\/h2>\n<p>A ball valve is not the right valve everywhere in a vacuum system, and we would rather tell you that up front than have it arrive and be wrong.<\/p>\n<div>\n<table style=\"min-width:700px;width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #ddd;padding:8px\">Position in the system<\/th>\n<th style=\"border:1px solid #ddd;padding:8px\">What it does there<\/th>\n<th style=\"border:1px solid #ddd;padding:8px\">Is a ball valve right for it?<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\"><strong>Fore-line \/ roughing line isolation<\/strong><\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">Between the pump and the chamber, on the roughing or backing line.<\/td>\n<td style=\"border:1px solid #ddd;padding:8px\"><strong>Yes \u2014 this is what a vacuum ball valve is for.<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\"><strong>Vacuum pump isolation<\/strong><\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">Shutting a pump out of the line so it can be serviced or swapped without venting the whole system.<\/td>\n<td style=\"border:1px solid #ddd;padding:8px\"><strong>Yes.<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\"><strong>Gauge isolation<\/strong><\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">Protecting a vacuum gauge during rough-down or venting.<\/td>\n<td style=\"border:1px solid #ddd;padding:8px\"><strong>Yes.<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\">High-vacuum chamber main valve<\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">The main gate between a chamber and a turbo pump, holding high or ultra-high vacuum.<\/td>\n<td style=\"border:1px solid #ddd;padding:8px\"><strong>\u0644\u0627 \u064a\u0648\u062c\u062f<\/strong> That is the job of an angle valve or a gate valve, not a ball valve. We will tell you so rather than sell you the wrong thing.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"font-size:13px;color:#666;margin:6px 0 28px\">\u2190 \u0645\u0631\u0631 \u0625\u0635\u0628\u0639\u0643 \u0639\u0644\u0649 \u0627\u0644\u062c\u062f\u0648\u0644 \u0644\u0639\u0631\u0636 \u062c\u0645\u064a\u0639 \u0627\u0644\u0623\u0639\u0645\u062f\u0629 \u2192<\/p>\n<p>If you are isolating a pump, a fore-line, or a gauge, a ball valve is the straightforward, fast, full-bore answer. If you are gating a chamber at high vacuum, you want an angle valve or a gate valve \u2014 a different tool for a different job.<\/p>\n<h2>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<div>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #ddd;padding:8px\">\u0627\u0644\u0639\u0646\u0635\u0631<\/th>\n<th style=\"border:1px solid #ddd;padding:8px\">\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\">\u0645\u0627\u062f\u0629 \u0627\u0644\u0647\u064a\u0643\u0644<\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">\u0627\u0644\u0641\u0648\u0644\u0627\u0630 \u0627\u0644\u0645\u0642\u0627\u0648\u0645 \u0644\u0644\u0635\u062f\u0623 ASTM 316<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\">\u0627\u0644\u0627\u062a\u0635\u0627\u0644<\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">\u0634\u0641\u0629 \u062a\u0641\u0631\u064a\u063a ISO-K \u2014 ISO80 (DN80\u060c 3 \u0628\u0648\u0635\u0627\u062a) \u0623\u0648 ISO100 (DN100\u060c 4 \u0628\u0648\u0635\u0627\u062a)<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\">Operating temperature<\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">\u221220 \u00b0C to +180 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\">\u0627\u0644\u0645\u0634\u063a\u0644<\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">Aluminium alloy cylinder, double acting (DA) or spring return (SR)<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\">Actuator mounting<\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">ISO 5211 \u2014 the actuator bolts straight onto the valve, no bracket or coupling<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\">Spring return position<\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">Normally closed or normally open \u2014 specify when ordering<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:8px\">\u0627\u0644\u062e\u062f\u0645\u0629<\/td>\n<td style=\"border:1px solid #ddd;padding:8px\">Automated isolation and sequencing on vacuum lines<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Why a Pneumatic Actuator Here<\/h2>\n<ul>\n<li><strong>Speed:<\/strong> vacuum sequences are timed. A hand valve makes the operator the bottleneck; an air actuator does not.<\/li>\n<li><strong>Direct mount:<\/strong> the valve body carries an ISO 5211 pad, so the actuator bolts on with no bracket, no coupling, nothing to align.<\/li>\n<li><strong>Spring return on air loss:<\/strong> an SR unit moves to the position you specified when the air supply goes. Tell us whether that position is open or closed and we will build it that way.<\/li>\n<li><strong>\u0628\u0643\u0627\u0645\u0644 \u0642\u0648\u062a\u0647\u0627:<\/strong> nothing narrows the line, so conductance is not sacrificed to the valve.<\/li>\n<\/ul>\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h2>\n<ul>\n<li><strong>Vacuum pump isolation<\/strong> \u2014 shutting a pump out for service without venting the system.<\/li>\n<li><strong>Vacuum coating and thin-film deposition<\/strong> \u2014 automated line sequencing between process steps.<\/li>\n<li><strong>Thermoforming<\/strong> \u2014 fast vacuum draw and release on a cycle.<\/li>\n<li><strong>Degassing and drying systems<\/strong> \u2014 repeated evacuate\/vent cycles under PLC control.<\/li>\n<li><strong>\u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0623\u063a\u0630\u064a\u0629<\/strong> \u2014 vacuum packing and tumbling lines.<\/li>\n<\/ul>\n<p>Related: the hand-operated version of this valve is our <a href=\"https:\/\/ballvalves.tw\/ar\/%d8%a7%d9%84%d9%85%d9%86%d8%aa%d8%ac\/%d8%b5%d9%85%d8%a7%d9%85-%d8%aa%d9%81%d8%b1%d9%8a%d8%ba-%d9%8a%d8%af%d9%88%d9%8a\/\">\u0635\u0645\u0627\u0645 \u062a\u0641\u0631\u064a\u063a \u064a\u062f\u0648\u064a<\/a>; for diverting between two vacuum lines, see the <a href=\"https:\/\/ballvalves.tw\/ar\/%d8%a7%d9%84%d9%85%d9%86%d8%aa%d8%ac\/%d8%b5%d9%85%d8%a7%d9%85-%d9%83%d8%b1%d9%88%d9%8a-%d8%ab%d9%84%d8%a7%d8%ab%d9%8a-%d8%a7%d9%84%d8%a7%d8%aa%d8%ac%d8%a7%d9%87%d8%a7%d8%aa-%d9%8a%d8%b9%d9%85%d9%84-%d8%a8%d8%a7%d9%84%d9%81%d8%b1%d8%a7\/\">3-way vacuum ball valve<\/a>. KF\/NW centering rings are <a href=\"https:\/\/ballvalves.tw\/ar\/%d8%a7%d9%84%d9%85%d9%86%d8%aa%d8%ac\/%d8%ad%d9%84%d9%82%d8%a9-%d8%a7%d9%84%d8%aa%d9%85%d8%b1%d9%83%d8%b2-%d8%a8%d8%a7%d9%84%d9%81%d8%b1%d8%a7%d8%ba-kf-nw\/\">here<\/a>.<\/p>\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<h3>Can I use this valve to isolate a high-vacuum chamber?<\/h3>\n<p>Not as the chamber&#8217;s main valve. A ball valve is the right tool for fore-line and roughing-line isolation, for shutting out a pump, and for protecting a gauge. For gating a chamber at high vacuum you want an angle valve or a gate valve. We would rather say so than sell you a valve that does not fit the job.<\/p>\n<h3>What flange sizes are available?<\/h3>\n<p>ISO-K in ISO80 (DN80, 3\u2033) and ISO100 (DN100, 4\u2033). The flange clamps straight into a standard ISO-K line \u2014 no adapter needed.<\/p>\n<h3>\u0627\u0644\u0622\u0644\u064a\u0629 \u062b\u0646\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0641\u0639\u0648\u0644 \u0623\u0645 \u0622\u0644\u064a\u0629 \u0627\u0644\u0631\u062c\u0648\u0639 \u0627\u0644\u0632\u0646\u0628\u0631\u0643\u064a \u2014 \u0623\u064a\u0647\u0645\u0627 \u064a\u062c\u0628 \u0623\u0646 \u0623\u062e\u062a\u0627\u0631\u061f<\/h3>\n<p>Double acting uses air to open and air to close, and holds its last position if the air supply is lost. Spring return uses air one way and a spring the other, so it moves to a preset position when air is lost. Tell us whether that position should be open or closed and we will build it that way.<\/p>\n<h3>What is the operating temperature range?<\/h3>\n<p>\u221220 \u00b0C to +180 \u00b0C.<\/p>\n<h3>Does the actuator need a bracket?<\/h3>\n<p>No. The valve body has an ISO 5211 mounting pad, so the actuator bolts straight on \u2014 nothing to machine, nothing to align.<\/p>\n<h3>\u0647\u0644 \u0647\u0646\u0627\u0643 \u062d\u062f \u0623\u062f\u0646\u0649 \u0644\u0643\u0645\u064a\u0629 \u0627\u0644\u0637\u0644\u0628\u061f<\/h3>\n<p>No. We have no MOQ. Tell us what you need and we will quote it.<\/p>","protected":false},"excerpt":{"rendered":"<p>A pneumatically actuated vacuum ball valve in 316 stainless steel, with an ISO-K flange that clamps straight into a standard line \u2014 ISO80 (DN80, 3\u2033) or ISO100 (DN100, 4\u2033). Full bore, \u221220 \u00b0C to +180 \u00b0C, double acting or spring return. The actuator bolts directly onto the ISO 5211 pad \u2014 no bracket, no coupling. For fore-line and pump isolation, not as a high-vacuum chamber gate.<\/p>\n<p><a style=\"display:inline-block;background:#c62828;color:#ffffff !important;padding:12px 22px;border-radius:6px;font-weight:bold;text-decoration:none\" href=\"https:\/\/ballvalves.tw\/ar\/%d8%a7%d9%84%d8%a7%d8%aa%d8%b5%d8%a7%d9%84\/\">\u0627\u0637\u0644\u0628 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631 \u2014 \u0633\u0646\u0631\u062f \u0639\u0644\u064a\u0643 \u0641\u064a \u063a\u0636\u0648\u0646 24 \u0633\u0627\u0639\u0629 \u2192<\/a><\/p>\n<p style=\"font-size:14px;color:#666666\">ISO 9001 \u00b7 CE \u00b7 \u0634\u0631\u0643\u0629 \u0645\u0635\u0646\u0639\u0629 \u0645\u0646\u0630 \u0639\u0627\u0645 1999<\/p>","protected":false},"featured_media":3980,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[78],"product_cat":[68],"product_tag":[],"class_list":["post-3850","product","type-product","status-publish","has-post-thumbnail","product_brand-yzng-trong","product_cat-vacuum-valve","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","taxable","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/product\/3850","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/media\/3980"}],"wp:attachment":[{"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/media?parent=3850"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/product_brand?post=3850"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/product_cat?post=3850"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/product_tag?post=3850"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}