{"id":5740,"date":"2026-11-27T09:58:54","date_gmt":"2026-11-27T01:58:54","guid":{"rendered":"https:\/\/ballvalves.tw\/?p=5740"},"modified":"2026-11-27T09:58:54","modified_gmt":"2026-11-27T01:58:54","slug":"flanged-ball-valve-guide","status":"publish","type":"post","link":"https:\/\/ballvalves.tw\/ar\/flanged-ball-valve-guide\/","title":{"rendered":"What Is a Flanged Ball Valve? Class 150\/300, JIS 10K\/20K and Dimensions"},"content":{"rendered":"<p class=\"last-updated\" style=\"margin:0 0 14px;font-size:0.9em;color:#555\">Last updated: 2026-11-27<\/p>\n<div class=\"short-answer\" style=\"border-left:4px solid #1b73df;background:#f3f7fc;padding:18px 22px;margin:0 0 28px;border-radius:0 6px 6px 0\">\n<p style=\"margin:0\"><strong>Short answer:<\/strong> A flanged ball valve is a quarter-turn shut-off valve with raised-face flanges cast onto both ends so it bolts straight between mating pipeline flanges. Instead of threaded WOG ratings, flanged ball valves are specified by flange standard and pressure class\u2014most commonly ANSI\/ASME Class 150 (275 psi ambient in stainless steel) or Class 300 (720 psi), and JIS 10K (1.0 MPa) or 20K (2.0 MPa). At Yzng Trong in Taiwan, we build full-port stainless steel flanged ball valves across all four standards from 1\/2\u2033 to 8\u2033, leak-tested one by one before shipment.<\/p>\n<\/div>\n<p class=\"wp-block-paragraph\">Once a stainless steel line steps past 2 inches\u2014or carries chemicals, treated water, or plant utilities that maintenance crews have to unbolt cleanly\u2014threaded ends become awkward to torque and seal. That is where a flanged ball valve takes over. You drop the valve between two counter-flanges with ring gaskets, tighten the stud bolts in a star pattern, and later pull the whole valve out for service without cutting pipe.<\/p>\n<p class=\"wp-block-paragraph\">The catch is that two flanged ball valves of the same nominal pipe size will not bolt into the same gap unless three numbers match: the flange drilling standard, the pressure class, and the face-to-face length. This guide breaks down how a flanged floating ball valve works, how ANSI Class 150\/300 and JIS 10K\/20K ratings compare, the exact mounting dimensions from 1\/2\u2033 to 8\u2033 from our catalog drawings, and the five specification mistakes that stall installations.<\/p>\n<p class=\"wp-block-paragraph\">We are Yzng Trong International Co., LTD., a stainless steel ball valve and actuator manufacturer in Taichung, Taiwan, operating our own factory since 1999. Standard values below follow ASME and JIS publications, and product dimensions come directly from our F-2 series catalog sheets.<\/p>\n<h2 class=\"wp-block-heading\">What Is a Flanged Ball Valve and How Does It Work?<\/h2>\n<p class=\"wp-block-paragraph\">A flanged ball valve uses a hollow, perforated stainless steel sphere that rotates 90 degrees between two seats to start or stop flow. When the bore aligns with the pipeline, flow passes straight through; a quarter turn brings the solid wall of the ball across the port for tight shut-off. Unlike threaded or welded valves, both ends terminate in integral flanges with bolt holes arranged around a fixed pitch circle.<\/p>\n<p class=\"wp-block-paragraph\">Inside our F-2 series <a href=\"https:\/\/ballvalves.tw\/ar\/%d8%a7%d9%84%d9%85%d9%86%d8%aa%d8%ac\/%d8%b5%d9%85%d8%a7%d9%85-%d9%83%d8%b1%d9%88%d9%8a-%d8%b0%d9%88-%d8%ad%d9%88%d8%a7%d9%81-%d9%8a%d8%af%d9%88%d9%8a\/\">stainless steel flanged ball valves<\/a>, four structural choices govern day-to-day performance:<\/p>\n<ul class=\"wp-block-list\">\n<li><strong>Two-piece split body:<\/strong> The body castings bolt together around the ball and seats. Unlike a one-piece unibody flanged valve that must be scrapped when seats wear out, a split-body valve can be unbolted from the line and opened on the bench to replace the seats and seals.<\/li>\n<li><strong>Full port (full bore) flow path:<\/strong> Every size from 1\/2\u2033 (15 mm bore) through 8\u2033 (200 mm bore) matches the nominal inside diameter of the pipe, keeping pressure drop low and allowing unobstructed flow on pump suction and transfer lines.<\/li>\n<li><strong>Floating ball mechanism:<\/strong> In sizes up to 8\u2033 at Class 150 \/ JIS 10K (and up to 4\u2033 at Class 300 \/ JIS 20K), the ball is supported between two resilient seats and allowed a tiny axial float. Upstream line pressure pushes the ball firmly into the downstream seat to assist the seal.<\/li>\n<li><strong>Blowout-proof stem:<\/strong> The stem inserts from inside the valve body with an integral lower shoulder wider than the stem bore, so internal line pressure cannot push the stem out even if packing hardware is loosened during maintenance.<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">When Should You Choose Flanged Over Threaded or Welded Ends?<\/h3>\n<p class=\"wp-block-paragraph\">Threaded valves are compact and economical on small utility branches, while socket-weld and butt-weld valves suit permanent lines where flanged joints are unwanted. Flanged ends earn their weight and bolt count on lines from 1-1\/2\u2033 to 8\u2033, at pump headers and skid boundaries that require periodic removal, and on existing plant piping already built with ASME or JIS flanges. For a side-by-side look at smaller-bore alternatives, see our guide to <a href=\"https:\/\/ballvalves.tw\/ar\/%d9%88%d8%b5%d9%84%d8%a7%d8%aa-%d8%b7%d8%b1%d9%81%d9%8a%d8%a9-%d9%84%d9%84%d8%b5%d9%85%d8%a7%d9%85%d8%a7%d8%aa\/\">butt weld, socket weld and threaded valve end connections<\/a>.<\/p>\n<h3 class=\"wp-block-heading\">Why Do Flanged Ball Valves Use Class or K Ratings Instead of WOG?<\/h3>\n<p class=\"wp-block-paragraph\">Buyers moving up from threaded valves often ask for a flanged valve with a cold water WOG figure. Industrial flanged valves are not rated by WOG because the bolting, flange thickness, and gasket seating stress are governed by flange standards\u2014<a href=\"https:\/\/www.asme.org\/codes-standards\/find-codes-standards\/b16-5-pipe-flanges-flanged-fittings\" target=\"_blank\" rel=\"noopener\">ASME B16.5<\/a> \u0648 <a href=\"https:\/\/www.asme.org\/codes-standards\/find-codes-standards\/b16-34-valves-flanged-threaded-welding-end\" target=\"_blank\" rel=\"noopener\">ASME B16.34<\/a> in North America, or JIS B 2220 in Japan and parts of Asia. If you want background on how cold working pressure labels work on threaded series, read our explainer on <a href=\"https:\/\/ballvalves.tw\/ar\/%d9%85%d8%b9%d8%af%d9%84-%d8%b6%d8%ba%d8%b7-%d8%a7%d9%84%d9%80%d9%88%d9%88%d8%ba\/\">\u0642\u064a\u0645 \u0627\u0644\u0636\u063a\u0637 \u0648\u0641\u0642\u064b\u0627 \u0644\u0645\u0639\u0627\u064a\u064a\u0631 WOG<\/a>.<\/p>\n<h2 class=\"wp-block-heading\">How Do ANSI Class 150\/300 and JIS 10K\/20K Pressure Ratings Compare?<\/h2>\n<p class=\"wp-block-paragraph\">A Class 150 ball valve is not limited to 150 psi, and a Class 300 ball valve is not capped at 300 psi. Those class numbers identify pressure-temperature tables in ASME B16.34: at ambient temperature in CF8M (cast 316 stainless steel), Class 150 allows up to 275 psi (about 19 bar) and Class 300 allows up to 720 psi (about 49.6 bar). JIS 10K and 20K follow JIS B 2220, rated at 1.0 MPa (about 145 psi) and 2.0 MPa (about 290 psi) at ambient conditions.<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th>Yzng Trong Model (Manual \/ Pneumatic)<\/th>\n<th>Flange Standard &amp; Class<\/th>\n<th>Governing Flange Spec<\/th>\n<th>Max Ambient Working Pressure (Stainless Steel)<\/th>\n<th>Manual Size Range<\/th>\n<th>Pneumatic Size Range<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>F-2B \/ F-2BM<\/strong><\/td>\n<td>ANSI \/ ASME Class 150 (150#)<\/td>\n<td>ASME B16.5 (RF)<\/td>\n<td>275 psi (approx. 19.0 bar)<\/td>\n<td>1\/2\u2033 \u2013 8\u2033<\/td>\n<td>1\/2 \u0628\u0648\u0635\u0629 \u2013 4 \u0628\u0648\u0635\u0627\u062a<\/td>\n<\/tr>\n<tr>\n<td><strong>F-2D \/ F-2DM<\/strong><\/td>\n<td>ANSI \/ ASME Class 300 (300#)<\/td>\n<td>ASME B16.5 (RF)<\/td>\n<td>720 \u0631\u0637\u0644 \u0644\u0643\u0644 \u0628\u0648\u0635\u0629 \u0645\u0631\u0628\u0639\u0629 (\u062d\u0648\u0627\u0644\u064a 49.6 \u0628\u0627\u0631)<\/td>\n<td>1\/2\u2033 \u2013 4\u2033*<\/td>\n<td>1\/2\u2033 \u2013 4\u2033*<\/td>\n<\/tr>\n<tr>\n<td><strong>F-2K \/ F-2KM<\/strong><\/td>\n<td>JIS 10K<\/td>\n<td>JIS B 2220 (RF)<\/td>\n<td>1.0 MPa (approx. 145 psi \/ 10 bar)<\/td>\n<td>1\/2\u2033 \u2013 8\u2033<\/td>\n<td>1\/2 \u0628\u0648\u0635\u0629 \u2013 4 \u0628\u0648\u0635\u0627\u062a<\/td>\n<\/tr>\n<tr>\n<td><strong>F-2E \/ F-2EM<\/strong><\/td>\n<td>JIS 20K<\/td>\n<td>JIS B 2220 (RF)<\/td>\n<td>2.0 MPa (approx. 290 psi \/ 20 bar)<\/td>\n<td>1\/2\u2033 \u2013 4\u2033*<\/td>\n<td>1\/2\u2033 \u2013 4\u2033*<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\" style=\"font-size:0.92em;color:#555\"><em>*Note: In our F-2D (Class 300) and F-2E (JIS 20K) series, standard catalog sizes are 1\/2\u2033, 3\/4\u2033, 1\u2033, 1-1\/2\u2033, 2\u2033, 2-1\/2\u2033, 3\u2033 and 4\u2033 (no 1-1\/4\u2033 size). All four standards use raised-face (RF) flanges.<\/em><\/p>\n<h3 class=\"wp-block-heading\">How Do PTFE and Graphite Seats Affect Temperature Limits?<\/h3>\n<p class=\"wp-block-paragraph\">The metal flange class sets the structural ceiling of the casting, but the soft seat inside the valve sets the practical operating temperature. Across our standard flanged ball valves, PTFE seats cover a working temperature range of <strong>\u221220 \u00b0C to +80 \u00b0C (\u22124 \u00b0F to +176 \u00b0F)<\/strong>, and allowable working pressure derates as service temperature rises.<\/p>\n<p class=\"wp-block-paragraph\">For low-pressure saturated steam or hot utility lines above 80 \u00b0C, we build a <strong>graphite-seat version up to +180 \u00b0C (+356 \u00b0F)<\/strong> on a made-to-order basis. If your line carries steam, send us your operating steam pressure and temperature when requesting a quote so we can confirm suitability; you can also review seat behavior in our article on <a href=\"https:\/\/ballvalves.tw\/ar\/ball-valve-for-steam\/\">using a ball valve for steam<\/a>.<\/p>\n<h2 class=\"wp-block-heading\">What Are the Key Flanged Ball Valve Dimensions (1\/2\u2033 to 8\u2033)?<\/h2>\n<p class=\"wp-block-paragraph\">When replacing an existing valve or laying out a new piping spool, three flanged ball valve dimensions must match the mating flange and gap: <strong>face-to-face length (L)<\/strong>, <strong>bolt circle diameter \/ PCD (\u00d8H)<\/strong>\u0648 <strong>bolt hole count \u00d7 hole diameter (N \u00d7 \u00d8M)<\/strong>. ANSI Class 150 and 300 face-to-face lengths follow <a href=\"https:\/\/www.asme.org\/codes-standards\/find-codes-standards\/b16-10-face-to-face-end-to-end-dimensions-valves\" target=\"_blank\" rel=\"noopener\">ASME B16.10<\/a>.<\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/stainless-steel-flanged-ball-valve-bodies-raised-face-iso5211.webp\" alt=\"Batch of cast stainless steel flanged ball valve bodies showing raised-face flanges and integral ISO 5211 mounting pads at Yzng Trong Taiwan factory\" class=\"wp-image-5738\" width=\"1200\" height=\"900\" srcset=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/stainless-steel-flanged-ball-valve-bodies-raised-face-iso5211.webp 1200w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/stainless-steel-flanged-ball-valve-bodies-raised-face-iso5211-300x225.webp 300w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/stainless-steel-flanged-ball-valve-bodies-raised-face-iso5211-1024x768.webp 1024w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/stainless-steel-flanged-ball-valve-bodies-raised-face-iso5211-768x576.webp 768w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/stainless-steel-flanged-ball-valve-bodies-raised-face-iso5211-16x12.webp 16w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/stainless-steel-flanged-ball-valve-bodies-raised-face-iso5211-600x450.webp 600w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">Cast stainless steel flanged ball valve bodies at our Taiwan factory, showing serrated raised-face (RF) flange surfaces and integral ISO 5211 top mounting pads.<\/figcaption><\/figure>\n<h3 class=\"wp-block-heading\">Table 1: ANSI Class 150 (F-2B) vs. JIS 10K (F-2K) Dimensions (mm)<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th>\u0627\u0644\u062d\u062c\u0645<\/th>\n<th>Bore \u00d8A<\/th>\n<th>Class 150 L (F2F)<\/th>\n<th>Class 150 Flange OD \u00d8K<\/th>\n<th>Class 150 PCD \u00d8H<\/th>\n<th>Class 150 Holes (N \u00d7 \u00d8M)<\/th>\n<th>JIS 10K L (F2F)<\/th>\n<th>JIS 10K Flange OD \u00d8K<\/th>\n<th>JIS 10K PCD \u00d8H<\/th>\n<th>JIS 10K Holes (N \u00d7 \u00d8M)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>1\/2\u2033<\/strong><\/td>\n<td>15<\/td>\n<td>108.0<\/td>\n<td>89.0<\/td>\n<td>60.5<\/td>\n<td>4 \u00d7 15.9<\/td>\n<td>110.0<\/td>\n<td>95<\/td>\n<td>70<\/td>\n<td>4 \u00d7 15<\/td>\n<\/tr>\n<tr>\n<td><strong>3\/4\u2033<\/strong><\/td>\n<td>20<\/td>\n<td>117.5<\/td>\n<td>98.0<\/td>\n<td>69.8<\/td>\n<td>4 \u00d7 15.9<\/td>\n<td>120.0<\/td>\n<td>100<\/td>\n<td>75<\/td>\n<td>4 \u00d7 15<\/td>\n<\/tr>\n<tr>\n<td><strong>1\u2033<\/strong><\/td>\n<td>25<\/td>\n<td>127.0<\/td>\n<td>108.0<\/td>\n<td>79.4<\/td>\n<td>4 \u00d7 15.9<\/td>\n<td>130.0<\/td>\n<td>125<\/td>\n<td>90<\/td>\n<td>4 \u00d7 19<\/td>\n<\/tr>\n<tr>\n<td><strong>1-1\/4 \u0628\u0648\u0635\u0629<\/strong><\/td>\n<td>32<\/td>\n<td>139.4<\/td>\n<td>117.0<\/td>\n<td>88.9<\/td>\n<td>4 \u00d7 15.9<\/td>\n<td>140.0<\/td>\n<td>135<\/td>\n<td>100<\/td>\n<td>4 \u00d7 19<\/td>\n<\/tr>\n<tr>\n<td><strong>1-1\/2 \u0628\u0648\u0635\u0629<\/strong><\/td>\n<td>38<\/td>\n<td>165.1<\/td>\n<td>127.0<\/td>\n<td>98.5<\/td>\n<td>4 \u00d7 16.0<\/td>\n<td>165.0<\/td>\n<td>140<\/td>\n<td>105<\/td>\n<td>4 \u00d7 19<\/td>\n<\/tr>\n<tr>\n<td><strong>2\u2033<\/strong><\/td>\n<td>50<\/td>\n<td>177.8<\/td>\n<td>152.4<\/td>\n<td>120.6<\/td>\n<td>4 \u00d7 19.0<\/td>\n<td>180.0<\/td>\n<td>155<\/td>\n<td>120<\/td>\n<td>4 \u00d7 19<\/td>\n<\/tr>\n<tr>\n<td><strong>2-1\/2 \u0628\u0648\u0635\u0629<\/strong><\/td>\n<td>65<\/td>\n<td>190.5<\/td>\n<td>177.8<\/td>\n<td>139.7<\/td>\n<td>4 \u00d7 19.0<\/td>\n<td>191.0<\/td>\n<td>175<\/td>\n<td>140<\/td>\n<td>4 \u00d7 19<\/td>\n<\/tr>\n<tr>\n<td><strong>3\u2033<\/strong><\/td>\n<td>80<\/td>\n<td>203.2<\/td>\n<td>190.5<\/td>\n<td>152.4<\/td>\n<td><strong>4 \u00d7 19.0<\/strong><\/td>\n<td>200.0<\/td>\n<td>185<\/td>\n<td>150<\/td>\n<td><strong>8 \u00d7 19<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>4\u2033<\/strong><\/td>\n<td>100<\/td>\n<td>228.6<\/td>\n<td>228.6<\/td>\n<td><strong>190.5<\/strong><\/td>\n<td>8 \u00d7 19.0<\/td>\n<td>230.0<\/td>\n<td>210<\/td>\n<td><strong>175<\/strong><\/td>\n<td>8 \u00d7 19<\/td>\n<\/tr>\n<tr>\n<td><strong>5\u2033<\/strong><\/td>\n<td>125<\/td>\n<td><strong>356.0<\/strong><\/td>\n<td>254.0<\/td>\n<td>215.9<\/td>\n<td>8 \u00d7 22.0<\/td>\n<td><strong>300.0<\/strong><\/td>\n<td>250<\/td>\n<td>210<\/td>\n<td>8 \u00d7 23<\/td>\n<\/tr>\n<tr>\n<td><strong>6\u2033<\/strong><\/td>\n<td>150<\/td>\n<td><strong>394.0<\/strong><\/td>\n<td>279.4<\/td>\n<td>241.3<\/td>\n<td>8 \u00d7 22.0<\/td>\n<td><strong>340.0<\/strong><\/td>\n<td>280<\/td>\n<td>240<\/td>\n<td>8 \u00d7 23<\/td>\n<\/tr>\n<tr>\n<td><strong>8\u2033<\/strong><\/td>\n<td>200<\/td>\n<td>457.2<\/td>\n<td>342.9<\/td>\n<td>298.4<\/td>\n<td><strong>8 \u00d7 22.0<\/strong><\/td>\n<td>457.0<\/td>\n<td>330<\/td>\n<td>290<\/td>\n<td><strong>12 \u00d7 23<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">Table 2: ANSI Class 300 (F-2D) vs. JIS 20K (F-2E) Dimensions (mm)<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th>\u0627\u0644\u062d\u062c\u0645<\/th>\n<th>Bore \u00d8A<\/th>\n<th>Face-to-Face L (Both)<\/th>\n<th>Class 300 Flange OD \u00d8K<\/th>\n<th>Class 300 PCD \u00d8H<\/th>\n<th>Class 300 Holes (N \u00d7 \u00d8M)<\/th>\n<th>JIS 20K Flange OD \u00d8K<\/th>\n<th>JIS 20K PCD \u00d8H<\/th>\n<th>JIS 20K Holes (N \u00d7 \u00d8M)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>1\/2\u2033<\/strong><\/td>\n<td>15<\/td>\n<td>140.0<\/td>\n<td>95<\/td>\n<td>66.7<\/td>\n<td>4 \u00d7 15.9<\/td>\n<td>95<\/td>\n<td>70<\/td>\n<td>4 \u00d7 15<\/td>\n<\/tr>\n<tr>\n<td><strong>3\/4\u2033<\/strong><\/td>\n<td>20<\/td>\n<td>152.0<\/td>\n<td>117<\/td>\n<td>82.6<\/td>\n<td>4 \u00d7 19<\/td>\n<td>100<\/td>\n<td>75<\/td>\n<td>4 \u00d7 15<\/td>\n<\/tr>\n<tr>\n<td><strong>1\u2033<\/strong><\/td>\n<td>25<\/td>\n<td>165.0<\/td>\n<td>124<\/td>\n<td>88.9<\/td>\n<td>4 \u00d7 19<\/td>\n<td>125<\/td>\n<td>90<\/td>\n<td>4 \u00d7 19<\/td>\n<\/tr>\n<tr>\n<td><strong>1-1\/2 \u0628\u0648\u0635\u0629<\/strong><\/td>\n<td>38<\/td>\n<td>190.0<\/td>\n<td>155.5<\/td>\n<td>114.3<\/td>\n<td>4 \u00d7 22<\/td>\n<td>140<\/td>\n<td>105<\/td>\n<td>4 \u00d7 19<\/td>\n<\/tr>\n<tr>\n<td><strong>2\u2033<\/strong><\/td>\n<td>50<\/td>\n<td>216.0<\/td>\n<td>165.1<\/td>\n<td>127.0<\/td>\n<td><strong>8 \u00d7 19<\/strong><\/td>\n<td>155<\/td>\n<td>120<\/td>\n<td><strong>8 \u00d7 19<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>2-1\/2 \u0628\u0648\u0635\u0629<\/strong><\/td>\n<td>65<\/td>\n<td>241.0<\/td>\n<td>190.5<\/td>\n<td>149.3<\/td>\n<td>8 \u00d7 22<\/td>\n<td>175<\/td>\n<td>140<\/td>\n<td>8 \u00d7 19<\/td>\n<\/tr>\n<tr>\n<td><strong>3\u2033<\/strong><\/td>\n<td>80<\/td>\n<td>283.0<\/td>\n<td>209.5<\/td>\n<td>168.1<\/td>\n<td>8 \u00d7 22<\/td>\n<td>200<\/td>\n<td>160<\/td>\n<td>8 \u00d7 23<\/td>\n<\/tr>\n<tr>\n<td><strong>4\u2033<\/strong><\/td>\n<td>100<\/td>\n<td>305.0<\/td>\n<td>254.0<\/td>\n<td>200.1<\/td>\n<td>8 \u00d7 22<\/td>\n<td>225<\/td>\n<td>185<\/td>\n<td>8 \u00d7 23<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">Full catalog sheets\u2014including flange thickness (T), raised-face diameter (F), and ISO mounting pad details\u2014are available as PDF downloads on our <a href=\"https:\/\/ballvalves.tw\/ar\/%d8%a7%d9%84%d9%85%d9%86%d8%aa%d8%ac\/%d8%b5%d9%85%d8%a7%d9%85-%d9%83%d8%b1%d9%88%d9%8a-%d8%b0%d9%88-%d8%ad%d9%88%d8%a7%d9%81-%d9%8a%d8%af%d9%88%d9%8a\/\">manual flanged ball valve page<\/a> (<a href=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/F-2B-Flange-Ball-Valve-150LB-Catalog.pdf\">F-2B Class 150 PDF<\/a>, <a href=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/F-2D-Flange-Ball-Valve-300LB-Catalog.pdf\">F-2D Class 300 PDF<\/a>, <a href=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/F-2K-Flange-Ball-Valve-10K-Catalog.pdf\">F-2K JIS 10K PDF<\/a>\u0648 <a href=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/F-2E-Flange-Ball-Valve-20K-Catalog.pdf\">F-2E JIS 20K PDF<\/a>).<\/p>\n<h2 class=\"wp-block-heading\">Can You Bolt a JIS 10K Valve onto an ANSI Class 150 Flange? (5 Common Mistakes)<\/h2>\n<p class=\"wp-block-paragraph\">No\u2014JIS 10K and ANSI Class 150 flanges are not interchangeable. Even where a 2-inch flanged ball valve looks deceptively close on paper (120 mm vs. 120.6 mm PCD), forcing mismatched flanges binds stud bolts, unloads one side of the gasket, and fails at the worst sizes completely. Below are the five mistakes we see most often on flanged valve inquiries:<\/p>\n<ol class=\"wp-block-list\">\n<li><strong>Mixing JIS 10K and ANSI Class 150 on imported skids:<\/strong> North American plants buying Japanese, Korean, or Taiwanese process skids frequently assume a 3\u2033 or 4\u2033 flange is universal. Look at Table 1: on a <strong>3\u2033 valve<\/strong>, ANSI Class 150 has <strong>4 bolt holes<\/strong> on a 152.4 mm circle, while JIS 10K has <strong>8 bolt holes<\/strong> on a 150 mm circle. On a <strong>4\u2033 valve<\/strong>, both use 8 holes, but the bolt circles sit 15.5 mm apart (190.5 mm vs. 175 mm). Always verify the stamp on the mating pipe flange before ordering.<\/li>\n<li><strong>Checking pipe size without checking face-to-face length (L):<\/strong> In rigid flanged pipework, the gap between existing weld-neck flanges will not stretch. A 2\u2033 Class 150 valve is 177.8 mm long, while a 2\u2033 Class 300 valve is 216.0 mm long (and switches from 4 bolts to 8 bolts). Even between Class 150 and JIS 10K at 6\u2033, the face-to-face jump is 54 mm (394.0 mm vs. 340.0 mm). Interestingly, as Table 2 shows, our Class 300 (F-2D) and JIS 20K (F-2E) castings share identical face-to-face lengths from 1\/2\u2033 to 4\u2033, yet their bolt circles still will not mate.<\/li>\n<li><strong>Looking at ambient flange pressure while ignoring the 80 \u00b0C PTFE seat limit:<\/strong> Specifying Class 300 for a 150 \u00b0C steam line with standard PTFE seats leads to softened, extruded seats. Match the seat material to the temperature first: standard PTFE for \u221220 \u00b0C to +80 \u00b0C, or our made-to-order graphite-seat configuration up to +180 \u00b0C.<\/li>\n<li><strong>Choosing 304 vs. 316 by general &#8220;acid\/alkali&#8221; labels instead of chlorides:<\/strong> Both CF8 (cast 304) and CF8M (cast 316) handle general water, air, and mild process utilities, while carbon steel bodies can be made to order when quantity justifies a run. As the <a href=\"https:\/\/www.imoa.info\/molybdenum-uses\/molybdenum-grade-stainless-steels\/molybdenum-grade-stainless-steel-faq.php\" target=\"_blank\" rel=\"noopener\">International Molybdenum Association (IMOA)<\/a> notes, the molybdenum addition in 316 stainless steel specifically raises resistance to chloride pitting and crevice attack\u2014making CF8M the safer specification for coastal air, brackish cooling water, and chloride-bearing chemical lines. See our <a href=\"https:\/\/ballvalves.tw\/ar\/cf8m-material\/\">CF8M ball valve specification guide<\/a> for details.<\/li>\n<li><strong>Ordering a standard manual lever valve when automation is planned:<\/strong> Manual F-2 valves come with a lever handle (no locking device on this series) up to 8\u2033. If you need remote PLC control or plan to add an actuator, specify our <a href=\"https:\/\/ballvalves.tw\/ar\/%d8%a7%d9%84%d9%85%d9%86%d8%aa%d8%ac\/%d8%b5%d9%85%d8%a7%d9%85-%d9%83%d8%b1%d9%88%d9%8a-%d8%b0%d9%88-%d8%ad%d9%88%d8%a7%d9%81-%d9%87%d9%88%d8%a7%d8%a6%d9%8a\/\">pneumatic flanged ball valve (F-2BM \/ F-2DM \/ F-2KM \/ F-2EM)<\/a> in 1\/2\u2033 to 4\u2033. It uses a dedicated direct-mount body with an integral ISO 5211 top pad\u2014no separate bracket or coupling\u2014and leaves our factory assembled with our own rack-and-pinion actuator (4\u20138 bar air supply, Double Acting (DA) or Spring Return (SR)), stroke-tested and torque-tested as a complete unit.<\/li>\n<\/ol>\n<h2 class=\"wp-block-heading\">Where Are Stainless Steel Flanged Ball Valves Used?<\/h2>\n<p class=\"wp-block-paragraph\">Because a two-piece split-body flanged valve combines full-bore flow with straightforward unbolting for seat replacement, it is the standard shut-off choice across medium-bore industrial headers:<\/p>\n<ul class=\"wp-block-list\">\n<li><strong>Chemical processing lines:<\/strong> Process and utility header isolation where CF8M (cast 316) resists chloride pitting and PTFE seats handle aggressive media within \u221220 \u00b0C to +80 \u00b0C.<\/li>\n<li><strong>Water and wastewater treatment plants:<\/strong> Raw-water intake, pump discharge isolation, filtration skids, and dosing manifolds.<\/li>\n<li><strong>HVAC chilled and hot water headers:<\/strong> Chiller room and boiler header isolation at points cycled during seasonal maintenance.<\/li>\n<li><strong>Power plant auxiliary piping &amp; low-pressure steam:<\/strong> Treated cooling water within the \u221220 \u00b0C to +80 \u00b0C PTFE range, or plant utility saturated steam up to +180 \u00b0C using the made-to-order graphite-seat version.<\/li>\n<li><strong>Pulp and paper &amp; marine utility piping:<\/strong> General process water, shipboard grey water, and deck utility lines (for flanged non-return protection on the same headers, pair with our <a href=\"https:\/\/ballvalves.tw\/ar\/%d8%a7%d9%84%d9%85%d9%86%d8%aa%d8%ac\/%d8%b5%d9%85%d8%a7%d9%85-%d9%81%d8%ad%d8%b5-%d8%b0%d9%88-%d8%ad%d9%88%d8%a7%d9%81-304\/\">flanged swing check valve<\/a>).<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">How We Build and Test Flanged Valves at Our Taiwan Factory<\/h3>\n<p class=\"wp-block-paragraph\">At Yzng Trong, valve bodies, end caps, and balls are investment cast, then finished on CNC equipment and tested at our factory in Taichung\u2014and when an order calls for pneumatic actuation, we manufacture the pneumatic actuators, <a href=\"https:\/\/ballvalves.tw\/ar\/%d8%a7%d9%84%d9%85%d9%86%d8%aa%d8%ac\/%d8%b5%d9%85%d8%a7%d9%85-%d8%a7%d9%84%d9%85%d9%84%d9%81-%d8%a7%d9%84%d9%84%d9%88%d9%84%d8%a8%d9%8a\/\">NAMUR solenoid valves<\/a>\u0648 <a href=\"https:\/\/ballvalves.tw\/ar\/%d8%a7%d9%84%d9%85%d9%86%d8%aa%d8%ac\/%d9%85%d9%81%d8%aa%d8%a7%d8%ad-%d8%b5%d8%ba%d9%8a%d8%b1\/\">limit switch boxes<\/a> under the same roof. We cannot promise the lowest price on the market; what we focus on is thorough inspection so buyers do not open a crate full of leakers. Every flanged valve is pressure-tested per API 598 and checked dimensionally before shipment. Our ball valves carry ISO 9001 and CE certification, and a material test report (MTR) for the valve body, pressure test report, or Certificate of Origin is available on request.<\/p>\n<p class=\"wp-block-paragraph\">One example from our own order history is a steel mill customer we have supplied for over twenty years. Their main concern when choosing a flanged valve supplier was avoiding cut-corner castings and inconsistent material quality. Over two decades of repeat orders, we have supplied them with both manual and pneumatic stainless steel flanged ball valves across sizes in CF8 (cast 304) and CF8M (cast 316)\u2014each unit finished, leak-tested per API 598, and checked dimensionally at our Taiwan factory before shipping.<\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/pneumatic-flanged-ball-valve-jis-20k-iso5211-factory.webp\" alt=\"4-inch JIS 20K two-piece split-body stainless steel flanged ball valve direct-mounted with a rack-and-pinion pneumatic actuator at Yzng Trong factory\" class=\"wp-image-5739\" width=\"1200\" height=\"900\" srcset=\"https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/pneumatic-flanged-ball-valve-jis-20k-iso5211-factory.webp 1200w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/pneumatic-flanged-ball-valve-jis-20k-iso5211-factory-300x225.webp 300w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/pneumatic-flanged-ball-valve-jis-20k-iso5211-factory-1024x768.webp 1024w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/pneumatic-flanged-ball-valve-jis-20k-iso5211-factory-768x576.webp 768w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/pneumatic-flanged-ball-valve-jis-20k-iso5211-factory-16x12.webp 16w, https:\/\/ballvalves.tw\/wp-content\/uploads\/2026\/11\/pneumatic-flanged-ball-valve-jis-20k-iso5211-factory-600x450.webp 600w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">A 4-inch (DN100) JIS 20K two-piece split-body stainless steel flanged ball valve (F-2EM) factory-mounted with our rack-and-pinion pneumatic actuator via the integral ISO 5211 pad.<\/figcaption><\/figure>\n<h2 class=\"wp-block-heading\">How to Specify a Flanged Ball Valve on Your RFQ<\/h2>\n<p class=\"wp-block-paragraph\">To get an accurate quote without back-and-forth emails, include seven items on your request for quotation (you can also browse our full <a href=\"https:\/\/ballvalves.tw\/ar\/%d9%81%d8%a6%d8%a9+%d8%a7%d9%84%d9%85%d9%86%d8%aa%d8%ac\/flanged-ball-valve\/\">flanged ball valves category<\/a>):<\/p>\n<ul class=\"wp-block-list\">\n<li><strong>1. Nominal pipe size and quantity:<\/strong> 1\/2\u2033 to 8\u2033 for Class 150 \/ JIS 10K; 1\/2\u2033 to 4\u2033 for Class 300 \/ JIS 20K (and all pneumatic models).<\/li>\n<li><strong>2. Flange standard and class:<\/strong> ANSI Class 150, ANSI Class 300, JIS 10K, or JIS 20K (DIN PN10\/PN16 flanged tooling can also be quoted made to order).<\/li>\n<li><strong>3. Body grade:<\/strong> CF8 (cast 304) or CF8M (cast 316).<\/li>\n<li><strong>4. Media, working pressure, and temperature:<\/strong> Tell us whether standard PTFE (\u221220 \u00b0C to +80 \u00b0C) fits or if your line needs the made-to-order graphite-seat version (up to +180 \u00b0C).<\/li>\n<li><strong>5. Operation:<\/strong> Manual lever, or pneumatic rack-and-pinion\u2014if pneumatic, state Double Acting (DA) or Spring Return (SR), fail-open or fail-closed (built in at the factory and not field-reversible), air supply (4\u20138 bar), and any solenoid voltage or limit switch box.<\/li>\n<li><strong>6. Required documents or private labeling:<\/strong> Valve body MTR, API 598 test report, 3D STEP file, or private-label branding.<\/li>\n<li><strong>7. Destination and preferred Incoterm:<\/strong> Regular items ship from stock and everything else is made to order; MOQ depends on the product, and trial orders are welcome.<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\">Send us your line conditions and flange standard, and our team in Taiwan will confirm the exact model and quote it for you.<\/p>\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ballvalves.tw\/ar\/%d8%b7%d9%84%d8%a8-%d8%b9%d8%b1%d8%b6-%d8%a3%d8%b3%d8%b9%d8%a7%d8%b1\/\">\u0627\u0637\u0644\u0628 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631 \u2014 \u0633\u0646\u0631\u062f \u0639\u0644\u064a\u0643 \u0641\u064a \u063a\u0636\u0648\u0646 24 \u0633\u0627\u0639\u0629 \u2192<\/a><\/p>\n<h2 class=\"wp-block-heading\">\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<h3 class=\"wp-block-heading\">What does Class 150 mean on a flanged ball valve?<\/h3>\n<p class=\"wp-block-paragraph\">Class 150 is an ASME pressure-temperature class rather than a flat 150 psi limit. Under ASME B16.34, a CF8M (cast 316 stainless steel) Class 150 flanged ball valve is rated up to 275 psi (about 19 bar) at ambient temperature, with allowable pressure decreasing as fluid temperature rises. In service, standard PTFE seats also set a \u221220 \u00b0C to +80 \u00b0C temperature window unless you specify our made-to-order graphite-seat version (up to +180 \u00b0C).<\/p>\n<h3 class=\"wp-block-heading\">Are JIS 10K and ANSI Class 150 flanged ball valves interchangeable?<\/h3>\n<p class=\"wp-block-paragraph\">No. Their bolt circle diameters, bolt hole counts, and face-to-face lengths follow separate standards (JIS B 2220 vs. ASME B16.5 \/ B16.10). For example, a 3\u2033 ANSI Class 150 flange uses 4 bolt holes on a 152.4 mm circle, whereas a 3\u2033 JIS 10K flange uses 8 bolt holes on a 150 mm circle; on a 4\u2033 valve, the bolt circles differ by 15.5 mm (190.5 mm vs. 175 mm). Yzng Trong manufactures both standards, so match whichever flange is welded to your pipe.<\/p>\n<h3 class=\"wp-block-heading\">What is the face-to-face length of a 2-inch flanged ball valve?<\/h3>\n<p class=\"wp-block-paragraph\">Face-to-face length depends on the flange standard and pressure class. In Yzng Trong&#8217;s catalog, a 2\u2033 (DN50) full-port flanged ball valve measures 177.8 mm in ANSI Class 150 (F-2B), 180.0 mm in JIS 10K (F-2K), and 216.0 mm in both ANSI Class 300 (F-2D) and JIS 20K (F-2E). Always verify both the face-to-face gap and the bolt count (4 holes on 2\u2033 Class 150 \/ JIS 10K versus 8 holes on 2\u2033 Class 300 \/ JIS 20K) before ordering a replacement.<\/p>\n<h3 class=\"wp-block-heading\">Can I mount an actuator onto a manual flanged ball valve later?<\/h3>\n<p class=\"wp-block-paragraph\">If you plan to automate the valve now or in the future, order our direct-mount pneumatic flanged series (F-2BM, F-2DM, F-2KM, or F-2EM, available in 1\/2\u2033 to 4\u2033) rather than the standard manual F-2 casting. The M-series casting features an integral ISO 5211 top mounting pad so a pneumatic or electric actuator bolts directly to the valve with no bracket or coupling. Complete pneumatic assemblies ship factory-mounted, stroke-tested, and torque-tested.<\/p>\n<h3 class=\"wp-block-heading\">Should I specify CF8 (304) or CF8M (316) stainless steel for a flanged ball valve?<\/h3>\n<p class=\"wp-block-paragraph\">CF8 (cast 304) handles general water, compressed air, oil, and non-chloride plant utilities reliably at a lower material cost. Specify CF8M (cast 316) whenever the fluid or washdown environment contains chlorides\u2014such as coastal air, brackish water, or chemical dosing\u2014because the molybdenum in 316 resists chloride pitting and crevice corrosion.<\/p>\n<div class=\"author-box\" style=\"border:1px solid #d9e1ec;background:#f7f9fc;padding:18px 22px;margin:36px 0 0;border-radius:6px\">\n<p style=\"margin:0 0 6px\"><strong>About the author<\/strong><\/p>\n<p style=\"margin:0\">David writes for ballvalves.tw, the site of Yzng Trong International Co., LTD., and has 30 years in the valve industry.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Last updated: 2026-11-27 Short answer: A flanged ball valve is a quarter-turn shut-off valve with raised-face flanges cast onto both ends so it bolts straight between mating pipeline flanges. Instead of threaded WOG ratings, flanged ball valves are specified by flange standard and pressure class\u2014most commonly ANSI\/ASME Class 150 (275 psi ambient in stainless steel) [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":5737,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[],"class_list":["post-5740","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-how-to-guides-tutorials"],"_links":{"self":[{"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/posts\/5740","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/comments?post=5740"}],"version-history":[{"count":1,"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/posts\/5740\/revisions"}],"predecessor-version":[{"id":5741,"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/posts\/5740\/revisions\/5741"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/media\/5737"}],"wp:attachment":[{"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/media?parent=5740"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/categories?post=5740"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ballvalves.tw\/ar\/wp-json\/wp\/v2\/tags?post=5740"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}